Fan Stage Start Temperature; Minimum Fan Speed; Adjusting # Of Degrees To Reach 100% Of Stages 1 & 2 - Airstream EXPERT 2V2SA User Manual

Table of Contents

Advertisement

EXPERT 2V2SA
6.2.2.

Fan Stage Start Temperature

1. From the main menu, select the option that
corresponds to the fan stage you want to
adjust:
STAGE 2
or
STAGES 3-
2. Use the navigation keys to select these
parameters:
Stage x
StartT°: 75.0°F
Stop T°: 74.0°F
3. Set the following parameters:
(The parameter adjustment process is explained
in section 3.2 on page 8).
Start T° — Set the start temperature of
the selected fan stage.
Stop T° — Set the stop temperature of the
selected fan stage.
The minimum difference between
two consecutive start temperatures
is 0.5 °F (0.3 °C).
The start temperature of a fan stage
must be greater value than its stop
temperature.
24
EXPERT 2V2SA, rev.10

6.2.3. Minimum Fan Speed

1. From the main menu, select the option that
corresponds to the fan stage you want to
adjust:
MIN. SPEED/CURVE
(to set the min.fan speed of stage 1)
or
STAGE 2
(to set the min.fan speed of stage 2)
2. Use the navigation keys to select this
screen:
Minimum Speed
40%
3. Set the minimum speed of the fans that
are associated with the selected fan stage
(10 to 100%) *This parameter can only be
modified while the minimum ventilation curve
is off (see section 6.1.4 on page 22).
6.2.4. Adjusting # of Degrees to
Reach 100% of Stages 1 & 2
1. From the main menu, select the option that
corresponds to the fan stage you want to
adjust:
STAGE 1
STAGE 2
2. Use the navigation keys to select the start
temperature screen:
Degrees to 100%
2.0°F
3. Set the number of degrees required for
the selected fan stage to reach its full
speed (0.5°F to 20.0°F (0.3°C and
11.1°C)).