EXPERT 2V2SA
the outside temperature sensor is enabled above.
Out T° compens.
Min Speed?
No
Use Outside Temperature Compensation
on Stages 1 & 2 — Select "Yes" to acti-
vate the outside temperature compensa-
tion on the number of degrees required
to reach 100% of fan stage 1 and 2 (see
section 6.3). **This parameter is accessible if
the outside temperature sensor is enabled above.
Out T° compens.
stage1?
Out T° compens.
stage2?
Winter& Summer Reference T° — Set the
temperature that signals the beginning of
winter and summer. *This parameter is ac-
cessible if the outside compensation function is
enabled above.
Outside T° in
winter:
41.0°F
Outside T° in
summer:
59.0°F
Use the Static Pressure Sensor — Select
"Yes" if a static pressure sensor is con-
nected to the controller.
Use Stat. P
sensor?
Yes
12
EXPERT 2V2SA, rev.10
Use the Static Pressure Compensation —
Select "Yes" to use inlets to compensate
for high or low pressure levels (see sec-
tion 11.3 on page 44). *This parameter
is accessible if the static pressure sensor and
inlet are enabled.
Use Stat. P
compens.?
No
Heaters and 0-10V Outputs — Enable the
desired number of heating stages (refer to
the stage combination table in section 4.4
on page 11). Up to two heater stages
can be used. Then, set the number of 0-10V
output (0-1 output).
#Heaters:
1
#0-10V
1
0-10V Output Used for — Select the
operating mode of the 0-10V output:
Ventilation / Heating / Chimney damper /
Heat mat. *This parameter is accessible if the
0-10V output is enabled above.
0-10V used for
Ventilation
0-10V follows the Set Point ? — Select
"Yes" if the start temperature of the
0-10V output is related to the set point.
This means that when the set point
changes, the start temperature is adjusted
by the same amount. Select "No" to use an
absolute start temperature for this output.
*This parameter is accessible if the 0-10V output
is enabled above.
0-10V follows
setpoint?
No
Use 0-10V Curve — If the 0-10V is used for
heating, it is possible to define a 10-point
curve to change its start temperature of
over time. Select "Yes" to enable this func-
tion or "No" to disable it. *This parameter
is accessible if the 0-10V output function is set
to "Heating" or to "Heat mat" above and if the
output does not follow the Set Point.