Table of Contents

Advertisement

EXPERT 2V2SA
7.

MIST COOLING

The mist output operates according to two
different timers whose activation are based
on the room temperature. Refer to the User
Setup Menu section to enable the mist output
and to see which stage of your controller is
used for this purpose.
The start and stop temperatures of both mist
timers are directly related to the set point.
This means that when the main set point
changes, the start and stop temperatures are
adjusted by the same amount.
Mist Timer
Mist
Status
ON
OFF
Time On
Mist Operation
Mist
Timer
Timer
2
Timer
1
Off
The misting & soaking devices are
sharing the same output. When the
clean mode is OFF, this output op-
erates according to the mist param-
eters; it runs according to the soaking
parameters when the clean mode is
ON. Refer to chapter 4.5 for further
information about the clean mode.
Time
Time Off
Room
Settings
1. From the main menu, select: MIST/SOAK.
2. Use the navigation keys to select these
parameters:
Mist Timer 1
StartT°
85.0°F
StopT°
83.0°F
On:
1:00min
Off:
10:00min
Mist Timer 2
StartT°
88.0°F
(...)
Mist Shutoff at
95%
These parameters are accessible if the mist output
is enabled in the User Setup Menu.
3. Set the following parameters:
(The parameter adjustment process is explained
in section 3.2 on page 8).
Mist Timer 1-2 Start T° — Set the start
temperature of both timers. Note that the
start temperature of the second timer must
be at least 0.5°F (0.3°C) higher than the
start temperature of the first timer.
Mist Timer 1-2 Stop T° — Set the stop
temperature and of both timers. Note that
the stop temperature of a given timer must
be at least 0.5°F (0.3°C) lower than its
start temperature.
Time On & Time Off — Set the Time On
and Time Off of both timers.
Mist Shutoff at — Set the humidity level
over which the mist units must stop being
used. This value ranges from 40 to 99%
of humidity. You can disable it by setting
this value to "Off" (100%) *This parameter
is accessible if the humidity sensor is enabled in
the User Setup Menu.
EXPERT 2V2SA, rev. 10
31

Advertisement

Table of Contents
loading

Table of Contents