8.

SOAKING

The controller can use the mist/soak output
for soaking while being in clean mode. If
the soaking option is enabled, the controller
automatically activates the soaking output
in timer mode when the clean mode starts.
The user can specify the number of soak-
ing cycles that need to be performed or can
choose to make them run continuously.
The misting & soaking devices are
sharing the same output. When
the clean mode is OFF, this output
operates according to the mist pa-
rameters; it runs according to the
soaking parameters when the clean
mode is ON. Refer to chapter 4.5
for further information about the
clean mode.
32
EXPERT 2V2SA, rev.10
Settings
1. From the main menu, select: MIST/SOAK.
2. Use the navigation keys to select these
parameters:
Soaking Timer
On:
10:00min
Soaking Timer
Off:
50:00min
# Soaking cycle
Cont.
These parameters are accessible if the soaking
output is enabled in the User Setup Menu.
3. Set the following parameters:
Time On & Off — The soaking timer is
made of a Time On and of a Time Off. The
Time On ranges from 0 to 3600 seconds
(1 hour) and the Time Off ranges from 0
to 240 minutes (4 hours). Set these pa-
rameters to the desired values.
# of soaking cycles — Select the num-
ber of soaking cycles that need to be
performed or select "cont." to run these
cycles continuously.