0-10V Fan Output - Airstream EXPERT 2V2SA User Manual

Table of Contents

Advertisement

EXPERT 2V2SA
6.6.

0-10V Fan Output

A 0-10V output can be used to activate
supplementary fans. Refer to the User Setup
Menu to enable this kind of output.
A 0 -10V fan output can operate as an
independent ventilation stage and use its
own temperature settings. The graph below
shows how this type of output works.
Independent 0-10V
Speed of the
0-10V fan
Maximum
Minimum
0%
• Below the start temperature: The output
follows a timer and runs at its minimum
speed;
• At the start temperature: The output oper-
ates continuously at its minimum speed, and
starts increasing in speed as the temperature
increases;
• At the maximum temperature: The output
reaches its maximum intensity;
• Above the stop temperature: The output
is deactivated.
To enable a independent 0-10V fan output,
set the operating mode of this output to
"Ventilation" in the User Setup Menu.
The start temperature of the independent
0-10V fan output can be set as an absolute
value or it can be related to the set point: this
Fan Output
Room T°
means that when the set point changes, the
start temperature is adjusted by the same
amount. Refer to the User Setup Menu to tell
if the start temperature of the 0-10V output
must follow the set point or not.
Settings
1. From the main menu, select the option:
0-10V OUTPUT
Make sure the function of the 0-10V
output is set to "Ventilation" in the
User Setup Menu before adjusting
the parameters below.
2. Use the navigation keys to select these
parameters:
StartT° 75.0°F
Min Spd
40%
Max Spd
100%
Max T°
77.0°F
Stop at 79.0°F
On:
15sec
Off
0sec
Probes
1234
3. Set the following parameters:
(The parameter adjustment process is explained
in section 3.2 on page 8).
Start T° — Set the start temperature of
the selected 0-10V output to the desired
value (-40 to 120°F (-40 to 48.9°C)).
Min / Man Spd — Set the minimum and
maximum speeds of the 0-10V fan output.
Max T° — Set the temperature at which
the 0-10V fan output reaches its full
speed This parameter ranges from 0.5 to
20°F (0.3°C to 11.1°C) above the start
temperature.
EXPERT 2V2SA, rev. 10