Manual Opening Of The Actuators - Airstream EXPERT 2V2SA User Manual

Table of Contents

Advertisement

EXPERT 2V2SA
11.2.2. Manual Opening of the
Actuators
The controller allows you to change the posi-
tion of the actuators manually. When an inlet
or chimney damper is controlled this way, the
controller simply stops controlling the output.
1. From the main menu, select the option that
corresponds to the type of air inlet you
want to adjust:
INLET
0-10V OUTPUT/CURVE
If you are selecting a 0-10V output,
make sure the function of this out-
put is set to "Chimney" in the User
Setup Menu before adjusting the
parameters below.
2. Use the navigation keys to select the fol-
lowing menu:
Opening
35%
Mode
Open
3. Set the Mode to the desired status: Open,
Close, Off or Auto.
Do not forget to return to the auto-
matic control mode afterwards so
that the controller can take back
control of this output.
EXPERT 2V2SA, rev. 10
43