Airstream EXPERT 2V2SA User Manual page 14

Table of Contents

Advertisement

EXPERT 2V2SA
De-icing Stage 2 — Select "Yes" if to en-
able the de-icing feature on fan stage 2.
Use de-icing on
stage 2?
No
Use Night Set Point — Select "Yes" to use
a night set point.
Use night setp?
Yes
Night Set Point Starts at — Select the time
at which the night set point starts being
used. *This parameter is accessible if the night
set point is enabled above.
Night setp at
8:00P
Day Set Point Starts at — Select the time
at which the day set point starts being
used by the controller. *This parameter is
accessible if the night set point is enabled above.
Day setp at:
7:30A
Transition Time — Set the transition time
between day and night set points to the
desired value. It can be adjusted from 15
to 120 minutes. *This parameter is accessible
if the night set point is enabled above.
Transition time
60 min
Low Temperature Override — Select "Yes"
to enable the low temperature override
functions: A) decrease the speed of stage
1 fans & stop stage 2 fans. B)Close the
air inlet further).
Low T° override
Yes
Override Below — Set the temperature
below which "Low temperature override"
options starts. This temperature is directly
related to the set point which means it is
automatically adjusted as the set point
changes and it ranges from 1°F to 40°F
(0.6 to 22.2°C) below the set point. *This
14
EXPERT 2V2SA, rev.10
parameter is accessible if the "Low temperature
override" feature is enabled above.
Override below
70.0°F
Override Stops at — Set the temperature
above which override functions stop.
This temperature is directly related to the
set point which means it is automatically
adjusted as the set point changes. *This
parameter is accessible if the "Low temperature
override" feature is enabled above.
Override stop at
75.0°F
Low Temperature Override Settings — Set
the minimum speed of stage 1 fans and the
inlet position that is reached when the "Low
Temperature override" function is enabled.
*This parameter is accessible if the "Low tem-
perature override" feature is enabled above.
Min spd
15%
Inlet
0%
Set point curve? — Select "Yes" to enable
the set point curve function.
Set point curve?
Yes
Min speed curve — Select "Yes" to enable
the minimum speed curve function.
Min speed curve?
Yes
Display — Select the desired LED display
amongst the following options:
- Temperature only (T° Only);
- Alternating display between temperature
and the static pressure (T° & SP);
- Alternating display between temperature
and the inlet position (T° & Inlet);
- Alternating display between temperature,
inlet position and static pressure (T° &
SP & Inlet).

Advertisement

Table of Contents
loading

Table of Contents