EXPERT 2V2SA
11.2.
Inlet & Chimney Settings
1. From the main menu, select the option that
corresponds to the type of air inlet you
want to adjust:
INLET
0-10V OUTPUT /CURVE
If you are selecting a 0-10V output,
make sure the function of this out-
put is set to "Chimney" in the User
Setup Menu before adjusting the
parameters below.
2. Use the navigation keys to select the fol-
lowing parameters:
Min Spd
45%
St. 0
10%
St. 1
20%
St. 1Hi
30%
...
St.
80%
Total run time
1:15min
Max opening
100%
Degrees to max
opening
2.0°F
Accuracy
+/- 2sec
...
Under run open
time
0sec
40
EXPERT 2V2SA, rev.10
3. Set the following parameters:
(The parameter adjustment process is explained
in section 3.2 on page 8).
Min Spd — During the minimum ventila-
tion cycles and in stage 1, the inlet will
use its minimum ventilation position (Step
1) as long as the fan speed is lower than
the "Min Speed" value. Once the minimum
speed is reached and keeps increasing the
inlet will open further towards Step 1 Hi
opening. Set the minimum fan speed to
the desired value.
St.x — Assign an actuator opening (in %)
with the startup of each fan stage.
St.x Hi — Assign the actuator opening (in
%) that must be used when a variable fan
stage reaches full speed
Total run time (inlet only) — Enter the
exact time that is required to reach the
actuator's maximum limit switch. The
controller will limit the opening of the inlet
according to this parameter value.
Max opening (inlet only) — Set the opening
that is reached beyond the start tempera-
ture of the last ventilation stage.*This pa-
rameter is accessible if the over-opening function
is enabled in the User Setup Menu.
Degrees to max opening (inlet only)— Set
the temperature range over which the ac-
tuator opens beyond its last stage opening
towards its maximum opening (see previ-
ous graph). This parameter ranges from
0.5 to 20°F (0.3 to 11.1°C).*This parameter
is accessible if the over-opening function is en-
abled in the User Setup Menu.
Accuracy (inlet only)— To prevent the
actuator from flickering, a minimum
opening or closing command is required
for the actuator to start moving. Set this
parameter to the desired value (from 1 to
15 seconds).