Regency P36-LPG4 Owners & Installation Manual

Gas log fireplace

Advertisement

Quick Links

Owners &
Installation
LISTINGS AND CODE APPROVALS
These gas appliances have been tested in
accordance with AS4553-2000, NZS 5262
and have been certifi ed by the Australian
Gas Association for installation and
operation as described in these Installation
and Operating Instructions.
Your unit should be serviced annually
by an authorised service person.
P36 Gas Log Fireplace
PLEASE KEEP THESE INSTRUCTIONS
FOR FUTURE REFERENCE
WARNING:
Improper installation, adjustment, alteration,
service or maintenance can cause injury or
property damage. Refer to this manual. For
assistance or additional information consult
an authorised installer, service agency or
the gas supplier.
FOR YOUR SAFETY
Do not store or use gasoline or other
fl ammable vapours and liquids in the vicinity
of this or any other appliance.
Installation and service must be performed
by an authorised installer, service agency or
the gas supplier.
918-538b
Models: P36-NG4
P36-LPG4
FOR YOUR SAFETY
What to do if you smell gas:
Do not try to light any
appliance
Do not touch any electrical
switch: do not use any
phone in your building.
Immediately call your gas
supplier from a neighbour's
phone. Follow the gas
supplier's instructions.
If you cannot reach your
gas supplier, call the fi re
department.
08/16/07

Advertisement

Table of Contents
loading

Summary of Contents for Regency P36-LPG4

  • Page 1 Installation and service must be performed by an authorised installer, service agency or the gas supplier. 918-538b Models: P36-NG4 P36-LPG4 FOR YOUR SAFETY What to do if you smell gas: Do not try to light any appliance Do not touch any electrical switch: do not use any phone in your building.
  • Page 2: To The New Owner

    TO THE NEW OWNER: Congratulations! You are the owner of a state-of-the-art Gas Log Fireplace by FPI FIREPLACE PRODUCTS INTERNATIONAL. The P36 has been designed to provide you with all the warmth and charm of a wood fi replace at the fl ick of a switch.
  • Page 3: Table Of Contents

    DATA BADGE Data Badge ...4 INSTALLATION Important Message ...5 Before You Start ...5 General Safety Information ...5 Installation Checklist ...5 Clearances ...6 Locating Your Gas fi replace ...6 Manufactured Mobile Home Additional Requirements ..6 Combustible Mantels ...7 Mantel Leg Clearances ...8 Framing And Finishing ...8 Unit Assembly Prior to Installation ...9 Flueing Introduction ...9...
  • Page 4: Data Badge

    DATA BADGE This is a copy of the label that accompanies each P36 Zero Clearance Room Sealed Gas Fireplace. We have printed a copy of the contents here for your review. The label is located on the front inside base of the unit, visible when the bottom louvre is open.
  • Page 5: Installation

    IMPORTANT MESSAGE SAVE THESE INSTRUCTIONS The P36-NG or P36-LPG Room Sealed Fireplace must be installed in accordance with AS5601- 2004 and NZS 5261 5261 and these instructions. Carefully read all the instructions in this manual fi rst. Consult the "authority having jurisdiction" to determine the need for a permit prior to starting the installation.
  • Page 6: Clearances

    INSTALLATION LOCATING YOUR GAS FIREPLACE 1) When selecting a location for your stove, ensure that the clearances outlined on this page are met. 2) P r o v i d e a d e q u a t e c l e a r a n c e s f o r servicing.
  • Page 7: Combustible Mantels

    INSTALLATION ® Regency P36-4 Gas Log Fireplace...
  • Page 8: Mantel Leg Clearances

    INSTALLATION MANTEL LEG CLEARANCES Combustible mantel leg clearances as per diagram below: 152m m Si de W al l Fi r epl ace Maximum 38mm projection 51m m at 51mm minimum 127m m clearance. Al l ow abl e m ant el l eg pr oj ect i on.
  • Page 9: Unit Assembly Prior To Installation

    UNIT ASSEMBLY PRIOR TO INSTALLATION The Top Facing Support, the Side Nailing Strips and the 2 Top Standoffs must be correctly positioned and attached to the top before unit is slipped into position. Top Standoff Assembly The top standoffs are shipped in a fl at position and must be folded into shape and attached.
  • Page 10: Exterior Flue Termination Locations

    INSTALLATION EXTERIOR FLUE TERMINATION LOCATIONS Minimum clearances required for balanced fl ue terminals or according to AS5601-2004 (AGA gas installation code) or NZS 5261 (New Zealand) Below eaves, balconies or other projections: - Appliances up to 50 MJ/h input - Appliances over 50 MJ/h input From the ground or above a balcony From a return wall or external corner From a gas meter (M)
  • Page 11: Flueing

    These fl ueing systems, in combination with the P36 Room Sealed Gas Fireplace, have been tested and listed as a Direct Vent type fl ue system by the Australian Gas Association. The location of the termination cap must conform to the requirements in the Flue Terminal Locations diagram in section "Exterior Flue Termination Locations."...
  • Page 12: Simpson Dura-Vent Flueing

    INSTALLATION SIMPSON DURA-VENT FLUEING The Simpson Dura-Vent Co Axial Flue System offers a complete line of component parts for installation of both horizontal and vertical installations. Many items are offered in decorative black, as well as galvanized fi nish. We recommend using the galvanized fi nish for installation with the P36. The minimum components required for a basic horizontal termination are: Horizontal Termination Cap...
  • Page 13: Flueing Arrangements - Horizontal Terminations

    FLUEING ARRANGEMENTS - HORIZONTAL TERMINATIONS SIMPSON DURA-VENT DIRECT VENT GS SYSTEM and REGENCY The diagram shows all allowable combinations of vertical runs with horizontal terminations, using one 90 one 90 elbow). Note: Must use optional fl ue adapter (Part # 510-994) when using Simpson Dura-Vent pipe. •...
  • Page 14: Flueing Arrangements - Horizontal Terminations

    INSTALLATION FLUEING ARRANGEMENTS - HORIZONTAL TERMINATIONS SIMPSON DURA-VENT DIRECT FLUE GS SYSTEM and REGENCY The diagram below shows examples of horizontal termination arrangements using two 90 Note: A maximum of two 90 elbows are permitted. A minimum of 6 ft. (1.8m) vertical from base of unit is required if two 90 Minimum distance between elbows is 2 ft.
  • Page 15: Flueing Arrangements - Vertical Terminations

    FLUEING ARRANGEMENTS - VERTICAL TERMINATIONS SIMPSON DURA-VENT CO AXIAL FLUE GS SYSTEM (LPG & NG) The P36 is approved for a 23 ft. (7.0m) vertical, with a maximum 12 ft. (3.7m) horizontal offset using two 90 elbows (two 45 elbows equal one 90 Flue GS fl...
  • Page 16 INSTALLATION The P36 is approved for a 37 ft. (11.3m) straight vertical, with Simpson Dura-Vent Co Axial Flue GS fl ue systems for LPG and NG, as per the diagram 3. The shaded area in the diagram 3 shows all allowable combinations of straight vertical and offset to vertical terminations with Simpson Dura- Vent Co Axial Flue GS fl...
  • Page 17: Horizontal Terminations

    HORIZONTAL TERMINATIONS Install the fl ue system according to the manufacturer's instructions included with the components. 1) Set the unit in its desired location. Check to determine if wall studs or roof rafters are in the way when the fl ueing system is attached.
  • Page 18: Vertical Terminations

    INSTALLATION VERTICAL TERMINATIONS 1) M a i n t a i n t h e 1 - 1 / 4 " clearances (air spaces) to combustibles when passing through ceilings, walls, roofs, enclosures, attic rafter, or other nearby combustible surfaces. Do not pack air spaces with insulation.
  • Page 19 Conversion Kit #513-968 from NG to LPG THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! Conversion Kit Contains: Qty. Part # Description 910-037 LPG Injector (Pilot Orifi ce) 904-390 Burner Orifi...
  • Page 20: Gas Line Installation

    INSTALLATION P36-NG System Data For 0 to 4500 feet altitude Burner Inlet Orifi ce Sizes: #37( 2.65mm) Max. Input Rating 33 mj Min. Input Rating 20 mj Supply Pressure min.1.25 kPa Manifold Pressure (High) 0.9 kPa Electrical: 240 V A.C. System. Circulation Fan: variable speed 130 CFM.
  • Page 21: Optional Brick Panels

    4) Light the pilot and turn the valve to "ON" position. 5) The pressure check should be carried out with the unit burning and the setting should be within the limits specifi ed on the safety label. 6) When fi nished reading manometer, turn off the gas valve, disconnect the hose and tighten the screw (clockwise) with a 1/8"...
  • Page 22 INSTALLATION 02-49 4) Place Log 02-51 on the front right side of the burner. Push the back of the log against the 2 brackets with the notch on the bottom right side of the log fi tting into the right side of the grate.
  • Page 23: Standard Flush Door

    10) Place the embers on the front of the burner tray in the places shown on the photo. Place embers in these 3 locations on the burner tray. Embers The standard fl ush door comes with a black frame. To install the frame, simply hook the top door fl...
  • Page 24: Premium Flush Front Installation

    INSTALLATION PREMIUM FLUSH FRONT INSTALLATION 1) Unplug the power source. 2) Remove the top louver (if fi tted) by carefully pulling it out. 3) Install the premium fl ush front top louver in place by sliding the louver tabs into the louver brackets on the inside top of the fi rebox. Louver Tab Premium Flush Front Top Louver in place.
  • Page 25 9) Connect the female connecter on the white wire to the TH terminal of the valve. 10) Remove the thermodisc cover from the thermodisc plate by undoing the 2 screws and then remove the wire grommet. Thermodisc Plate Thermodisc Cover Grommet 11) Take the white wire from the kit and the red wire from the burner ON/OFF switch and place the grommet thru the wires.
  • Page 26 INSTALLATION 15) Connect the thermodisc wire harness to the new valve/module wire harness. Refer to the wiring diagram on next page for details. 16) Mount the thermodisc bracket to the adjustable bracket using 2 screws. Important: Thermodisc location is crucial, check the data badge to identify unit and secure to screw location accordingly.
  • Page 27: Option 1: Wall Switch

    Option 1: WALL SWITCH 1) Run supplied 15' of wire through the right or left side gas inlet opening. Be careful not to damage wire. Note: We recommend a maximum of 15' of wire but if you wish to go with a longer run, use the Thermostat Wire Table.
  • Page 28: Wiring

    INSTALLATION This heater does not require a 240V A.C. supply for the gas control to operate. A 240V A.C. power supply is needed for the fan/blower operation. WARNING: Electrical Grounding Instructions This appliance is equipped with a three pronged (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle.
  • Page 29 INSTALLATION WIRING WITH PREMIUM FLUSH FRONT OPTION ® Regency P36-4 Gas Log Fireplace...
  • Page 30: Operating Instructions

    OPERATING INSTRUCTIONS OPTIONAL 240 Volt AC power is needed for the fan switch and blower. The fan can be hard wired if desired. A terminal block is provided on the left hand side of the unit. A three wire power cord can also be used and plugged into a suitable receptacle.
  • Page 31: Normal Operating Sounds Of Gas Appliances

    LIGHTING PROCEDURE 1) Push in gas control knob slightly and turn to “PILOT” position. 2) Push in control knob all the way and hold in until the pilot lights up. Continue to hold the control knob in for about 20 seconds after the pilot is lit.
  • Page 32: Copy Of The Lighting Plate Instructions

    OPERATING INSTRUCTIONS COPY OF THE LIGHTING PLATE INSTRUCTIONS Gas Inlet MAINTENANCE INSTRUCTIONS 1) Always turn off the gas valve before cleaning. For relighting, refer to lighting instructions. Keep the burner and control compartment clean by brushing and vacuuming at least once a year.
  • Page 33: Gold-Plated & Brass Louvres Or Trim

    3) Check for evidences of excessive condensation, such as water droplets forming in the inner liner, and subsequently dripping out the joints, Continuous condensation can cause corrosion of caps, pipe, and fi ttings. It may be caused by having excessive lateral runs, too many elbows, and exterior portions of the system being exposed to cold weather.
  • Page 34: Removing Valve

    MAINTENANCE REMOVING VALVE 1) Shut off the gas supply. 2) Remove the louvres (and bay door if it is on). 3) Open the fl ush door and remove the door. 4) Remove the logs. 5) Remove the burner/grate assembly by removing the two Phillips head screws and then lift the burner assembly out.
  • Page 35: Parts List

    Part # Description 910-142 Thermodisc-Fan Auto ON/OFF Thermodisc Bracket 948-045 Chain 948-025 Spring 510-125 Terminal Block Housing 910-006 Terminal Block 510-126 Terminal Block Cover 910-140 Fan Switch HIGH/OFF/LOW 10) 910-246 Burner Switch ON/OFF 12) 910-169/P Fan Motor 910-520 Wire Harness 910-714 Power Cord (240 V) 14) 510-026...
  • Page 36: Burner Assembly & Log Set

    PARTS LIST BURNER ASSEMBLY & LOG SET Part # Description 513-560/P Valve Assy - NG 513-562/P Valve Assy - LPG 52) * Valve Tray -NG 53) 430-055 Gasket - Valve Access Plate 54) 910-421 Pilot ON/OFF 3" Extension Knob 55) 910-422 HI/LOW 3"...
  • Page 37: Bay Front Assembly

    Part # Description 780-931 Bay Front Complete 103) 940-092/P Side Glass 107) 936-243 Glass Gasket - Soft Fibre Black 108) 940-094/P Center Glass 111) 780-905 Brick Panel Inlay - Rustic Brown Bay 780-906 Brick Panel Inlay - Old Town Red Bay 780-938 Bay Front Trim - Brass 780-936...
  • Page 38: Flush Front Accessories

    PARTS LIST Part # Description 132) 512-518 Flush Door Assembly 135) 940-090/P Glass (Flush) 136) 936-155 Glass Gasket (Tadpole) 904-691 U-Clip (each) 510-920 Flush Louvres - Gold/Black 510-921 Flush Louvres - Brass/Black 510-922 Flush Louvres - Black 510-923 Flush Louvres - Steel/Black 138) * Flush Louvre Assy-Top 139) *...
  • Page 39: Premium Flush Front Assembly

    PREMIUM FLUSH FRONT ASSEMBLY Part # Description 516-916 Premium Flush Front - Black 513-948 Wiring 910-975 Thermodisc 180) * Top Louver 181) * Bottom Louver 182) * Thermodisc Mounting Bracket 183) * Spacers *Not available as a replacement part. ® Regency P36-4 Gas Log Fireplace PARTS LIST...
  • Page 40: Cast Faceplate Assembly

    PARTS LIST Part # Description 513-971 Cast Faceplates (Set) - Black Metallic 201) * Cast Faceplate - Right 202) * Cast Faceplate - Top 203) * Cast Faceplate - Left 513-991 Cast Grills (Set) - Black Metallic (Aust. only 240 volt) 204) * Cast Grill - Top 205) *...
  • Page 41 NOTES ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ® Regency P36-4 Gas Log Fireplace...
  • Page 42 NOTES ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ® Regency P36-4 Gas Log Fireplace...
  • Page 43: Warranty

    Regency ® Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our door. FPI is pleased to extend this limited lifetime warranty to the original purchaser ®...
  • Page 44 Printed in Canada © Copyright 2007, FPI Fireplace Products International Ltd. All rights reserved.

This manual is also suitable for:

P36-ng4P36

Table of Contents