WIRING DIAGRAM

Though this heater does not require 120 volt AC supply for burner operation, it is recommended as a primary power source and is required for the optional
blower. Batteries should only be used as a secondary power source when power is lost within the home.
(Do not cut the ground terminal off under any circumstances.)
NOTE: Even if the fan is not purchased with the unit, it is still a good idea to bring power to the receptacle box (provided with the
unit) in case the fan is installed at a later date.
Note: If 120 volt power was not brought to appliance, batteries are required in both remote receiver (4 x AA batteries) & remote hand held (
3 x AAA batteries) in order to operate appliance using the remote control.
AC Adaptor
Caution: Ensure that the wires do not touch any
hot surfaces and are away from sharp edges.
Proflame System
Configuration
885
886 GTMF
Wire Diagram
SureFire™ Switch
CAUTION: Label all wires prior to disconnection
when servicing controls. Wiring errors can cause
improper and dangerous operation.
1 of 10
P36E-11 Zero Clearance Direct Vent Gas Fireplace