Regency P36-NG5 Owners & Installation Manual

Gas log fireplace

Advertisement

Quick Links

Owners &
Installation
LISTINGS AND CODE APPROVALS
These gas appliances have been tested in
accordance with AS4553-2000, NZS 5262
and have been certifi ed by the Australian
Gas Association for installation and
operation as described in these Installation
and Operating Instructions.
Your unit should be serviced annually
by an authorised service person.
P36 GAS LOG FIREPLACE
PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE
WARNING:
Improper installation, adjustment, alteration,
service or maintenance can cause injury or
property damage. Refer to this manual. For
assistance or additional information consult
an authorised installer, service agency or
the gas supplier.
FOR YOUR SAFETY
Do not store or use gasoline or other
fl ammable vapours and liquids in the vicinity
of this or any other appliance.
Installation and service must be performed
by an authorised installer, service agency or
the gas supplier.
918-538b
Models:
REFERENCE
FOR YOUR SAFETY
What to do if you smell gas:
Do not try to light any
appliance
Do not touch any electrical
switch: do not use any
phone in your building.
Immediately call your gas
supplier from a neighbour's
phone. Follow the gas
supplier's instructions.
If you cannot reach your
gas supplier, call the fi re
department.
P36-NG5
P36-LPG5
01/13/09

Advertisement

Table of Contents
loading

Summary of Contents for Regency P36-NG5

  • Page 1 Owners & Installation P36 GAS LOG FIREPLACE Models: P36-NG5 P36-LPG5 PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE WARNING: FOR YOUR SAFETY Improper installation, adjustment, alteration, What to do if you smell gas: service or maintenance can cause injury or Do not try to light any property damage.
  • Page 2: To The New Owner

    As it also bears our own mark, it promises to provide you with economy, comfort and security for many trouble free years to follow. Please take a moment now to acquaint yourself with these instructions and the many features of your Regency Fireplace.
  • Page 3: Table Of Contents

    Gas Pipe Pressure Testing ..........20 Optional Brick Panels ..........21 Log Set Installation ............21 Warranty ..............39 Standard Flush Door ...........23 Option 1: Wall Switch ..........24 Option 2: Remote Control ..........24 Option 3: Wall Thermostat ..........24 Thermostat Wire Table ..........24 Regency P36-5 Gas Log Fireplace ®...
  • Page 4: Data Badge

    DATA BADGE This is a copy of the label that accompanies The label is located on the front inside base of the DATA BADGE NOTE: Regency units are ® each P36 Zero Clearance Room Sealed Gas unit, visible when the bottom louvre is open.
  • Page 5: Installation

    14) Under no circumstances should any solid fuels (wood, paper, cardboard, coal, etc.) be used in this appliance. 15) The appliance area must be kept clear and free of combustible materials, (gases and other fl ammable vapours and liquids). Regency P36-5 Gas Log Fireplace ®...
  • Page 6: Clearances

    Note: For fl ue terminations see section " E x t e r i o r F l u e Te r m i n a t i o n Locations." Regency P36-5 Gas Log Fireplace ®...
  • Page 7: Combustible Mantels

    Mantel can be installed anywhere in shaded area or higher using the above scale. Note: Ensure the paint that is used on the mantel and the facing is "heat resistant" or the paint may discolour. Regency P36-5 Gas Log Fireplace...
  • Page 8: Mantel Leg Clearances

    4) The top of the unit must not be closer than 32" (813mm) to the ceiling. Maintain a physical gap between lining and spacers 2-5mm. (5mm clearance to framing each side). Regency P36-5 Gas Log Fireplace ®...
  • Page 9: Unit Assembly Prior To Installation

    1-1/4" / 32mm Each Co Axial Flue gas appliance must use it's own separate fl ue system. Common fl ue * For "C" screw position the top facing support systems are prohibited. is reversed. Regency P36-5 Gas Log Fireplace ®...
  • Page 10: Exterior Flue Termination Locations

    (IV) A fl ue terminal of this type shall not be located under a roofed area unless the roofed area is fully open on at least two sides and a free fl ow of air at the appliance is achieved. Regency P36-5 Gas Log Fireplace...
  • Page 11: Flueing

    2) Only Flex pipe purchased from Regency ® may be used for Flex installations. 3) If you are installing the P36 into a Regency Mantel Kit, use the minimum horizontal vent height (centre-line of 1029mm). Remember ® to include the mantel base in your calculations and to maintain the 32mm clearance (38mm with Flex) to the underside of the mantel top.
  • Page 12: Simpson Dura-Vent Flueing

    229 + 229mm 108 - 146mm 152 + 229mm Simpson Dura-Vent Co-Axial Flue GS SIMPSON DURA-VENT FLUEING COMPONENTS LIST All Simpson Dura-Vent components are available directly from Regency ® Part # Description Part # Description Part # Description 46DVA-06B 6" Pipe Length - Black Disc Elbow - Swivel - Galv.
  • Page 13: Flueing Arrangements - Horizontal Terminations

    6-7/8" (175mm) outer diameter A fl ue guard should be used whenever the termination is lower than the specifi ed minimum or as per local codes. Note: Regency ® Co Axial Flue System (Flex) is only approved for horizontal terminations.
  • Page 14: Flueing Arrangements - Horizontal Terminations

    INSTALLATION FLUEING ARRANGEMENTS - HORIZONTAL TERMINATIONS SIMPSON DURA-VENT DIRECT FLUE GS SYSTEM and REGENCY CO AXIAL FLUE SYSTEM (FLEX) ® (LPG & NG) The diagram below shows examples of horizontal termination arrangements using two 90 elbows (two 45 elbows equal one 90 elbow).
  • Page 15: Flueing Arrangements - Vertical Terminations

    • Maintain clearances to combustibles as listed in section "Clearances." Note: Must use optional fl ue adapter when using Simpson Dura-Vent pipe (Part # 510-994). Note: Regency ® Co Axial Flue System (Flex) is only approved for horizontal terminations. Diagram 2...
  • Page 16 • Flue must be supported at offsets • Firestops are required at each fl oor level and whenever passing through a wall. • Maintain clearances to combustibles as listed in section "Clearances." Diagram 3 Regency P36-5 Gas Log Fireplace ®...
  • Page 17: Horizontal Terminations

    Note: Apply sealant "Mill-Pac" to inner pipe fl ue pipe to the fl ue termination, slide the and high temperature silicone sealant Wall Thimble (Part # 620-926) over the fl ue to outer pipe on every pipe. twist-lock joint. Regency P36-5 Gas Log Fireplace ®...
  • Page 18: Vertical Terminations

    fl oor or ceiling of every level. To install the Firestop spacer in a fl at ceiling or wall, cut a 10 inch square hole. Frame the hole Diagram 5 as shown in Diagram 3 and install the fi restop. Regency P36-5 Gas Log Fireplace ®...
  • Page 19 23) Check operation of fl ame control. 15) Using the Allen wrench as shown in Fig.4, rotate the 24) Check for proper fl ame appearance and screw clockwise until snug, glow on logs. do not overtighten. Fig.4 Regency P36-5 Gas Log Fireplace ®...
  • Page 20: Gas Line Installation

    Log Set: Ceramic fi bre, 7 per set. connector. (If you are using rigid pipe, ensure Flue System: Simpson Dura-Vent Direct that the valve can be removed for servicing.) Flue System or Regency Direct ® Since some municipalities have additional local...
  • Page 21: Optional Brick Panels

    - do not force into position. 2) Sprinkle the vermiculite around the fi rebox base. Vermiculite Vermiculite Vermiculite 3) Place the Log 02-49 on the rear log support pins with the fl at side to the back. Regency P36-5 Gas Log Fireplace ®...
  • Page 22 fi tting into the 2nd grate tab. 02-55 02-53 02-52 02-50 02-53 Rear Grate 02-49 02-54 02-51 Photo shows rear grate tab. Notch Log 02-51 was removed to show the positioning of Log 02-52. 2nd Grate Tab Cutouts Regency P36-5 Gas Log Fireplace ®...
  • Page 23: Standard Flush Door

    If the optional premium fl ush front is used, the fan must run at minimum speed to prevent the unit from over heating. Over heating will cause automatic shutdown via the thermodisc safety switch. Diagram 2 Regency P36-5 Gas Log Fireplace ®...
  • Page 24: Option 1: Wall Switch

    WALL SWITCH REMOTE CONTROL WALL THERMOSTAT 1) Run supplied 15' of wire through the right Use the Regency ® Remote Control Kit approved A wall thermostat may be installed if desired, or left side gas inlet opening. Be careful not for this unit.
  • Page 25 If the optional premium fl ush front is used, the fan must run at minimum speed to prevent the unit from over heating. Over heating will cause automatic shutdown via the thermodisc safety switch. Regency P36-5 Gas Log Fireplace ®...
  • Page 26: Operating Instructions

    Ensure you maintain these fan again without a minimum of a 60 second motors on a regular basis by vacuuming wait. out the fan blades and housing using a soft brush nozzle. Regency P36-5 Gas Log Fireplace ®...
  • Page 27: Lighting Procedure

    "ON" position. room for a couple of hours. Blower: 4) Turn ON the fl ame switch. Regency gas appliances use high tech blowers ® The glass panel may require cleaning after the to push heated air farther into the room. It is not unit has cooled down.
  • Page 28: Copy Of The Lighting Plate Instructions

    Force or resistant paint. Regency uses StoveBright ® B)BEFORE LIGHTING smell all around attempted repair may result in a fire Paint - Metallic Black #6309.
  • Page 29: Gold-Plated & Brass

    fi nish and void the warranty. Clean any fi ngerprints off before turning the unit on. If the top louvres start to discolour, Your Regency fi replace is supplied with high ® check the door gasket seal and replace if temperature, 5 mm Neoceram ceramic glass that necessary.
  • Page 30: Maintenance

    (see Diagram 4). 10) Bring the fan to the front of the unit by 13) Reverse steps to reinstall. manuevering it out on an angle (see Diagram Diagram 4 Wire Harness Diagram 8 Regency P36-5 Gas Log Fireplace ®...
  • Page 31: Removing Valve

    8) Disconnect the 2 TP wires and the 2 TH wires from the valve. 9) Remove the 10 Phillips head screws securing the valve tray assembly in place (diagram 2) and then lift the entire assembly out diagram Regency P36-5 Gas Log Fireplace ®...
  • Page 32: Parts List

    Manual 513-968 Conversion Kit - NG to LPG BR I C K PAN EL SET D O O R S & LO U VER S PLEASE R EFER SEPAR ATE SEC TI O N Regency P36-5 Gas Log Fireplace ®...
  • Page 33: Burner Assembly & Log Set

    Middle Right Log 94) * Front Left Log 95) * Center Left Log 96) * Center Right Log 97) * Front Bottom Log 98) * Middle Left Log *Not available as a replacement part. Regency P36-5 Gas Log Fireplace ®...
  • Page 34: Flush Front Accessories

    Finishing Trim (4 piece) - Steel 157) * Finishing Trim Left 158) * Finishing Trim Top 159) * Finishing Trim Right 160) * Finishing Trim Bottom 161) 513-949 Flush Door Screen Pkg. *Not available as a replacement part. Regency P36-5 Gas Log Fireplace ®...
  • Page 35: Premium Flush Front Assembly

    Part # Description 516-946 Premium Flush Front - Black 179) 910-975 Thermodisc 180) * Top Louver 181) * Bottom Louver 182) * Thermodisc Mounting Bracket 183) * Spacers *Not available as a replacement part. Regency P36-5 Gas Log Fireplace ®...
  • Page 36: Warranty

    The warranty does not extend to any part or parts which show evidence of misuse or abuse, neglect, accident, lack of maintenance, or improper installation. Products made by other manufacturers and used in conjunction with the operation of this appliance without authorization from Regency , may ®...