Regency Panorama P36E-NG11 Owners & Installation Manual page 33

Zero clearance direct vent gas fireplace
Table of Contents

Advertisement

Horizontal Venting with Two (2) 90
One 90
elbow = Two 45
o
Option
V
H + H1
A)
0' Min.
2' Max.
B)
1' Min.
3' Max.
C)
2' Min.
4' Max.
D)
3' Min.
5' Max.
E)
4' Min.
6' Max.
F)
5' Min.
7' Max.
G)
6' Min.
8' Max.
Lengths do not include
elbow indicated
Horizontal Venting with Three (3) 90
One 90
elbow = Two 45
o
Option
V
H
A)
0' Min.
1' Max.
B)
1' Min.
2' Max.
C)
2' Min.
2' Max.
D)
3' Min.
2' Max.
E)
4' Min.
3 Max.
F)
5' Min.
4' Max. 10' Min. 7' Max.
G)
6' Min.
5' Max. 11' Min. 8' Max.
H)
7' Min.
6' Max. 12' Min. 9' Max.
Lengths do not include elbow indicated
Elbows
o
elbows.
o
W i t h t h e s e o p t i o n s ,
maximum total pipe length
is 30 feet with minimum
of 6 feet total vertical
and maximum 8 feet total
horizontal.
Please note minimum 1
foot between 90
elbows
o
is required.
Elbows
o
elbows.
o
V + V1
H + H1
With these options,
1' Min.
2' Max.
max. total pipe
3' Min.
3' Max.
length is 30 feet with
min. of 12 feet total
5' Min.
4' Max.
vertical and max. 9
feet total horizontal.
7' Min.
5' Max.
9' Min.
6' Max.
Please note min. 1
foot between 90
elbows is required.
H1
o
P36E-11 Zero Clearance Direct Vent Gas Fireplace
installation
V
|
33