Regency Panorama P36E-NG11 Owners & Installation Manual page 34

Zero clearance direct vent gas fireplace
Table of Contents

Advertisement

installation
Vertical Venting with Two (2) 90
One 90
elbow = Two 45
o
Option
V
A)
0' Min.
2' Max.
B)
1' Min.
4' Max.
C)
2' Min.
5' Max.
D)
3' Min.
6' Max.
E)
4' Min.
7' Max.
F)
5' Min.
8' Max.
Lengths do not include elbow indicated
For additional vertical venting with 2 x 90
Vertical Venting with Three (3) 90
One 90
elbow = Two 45
o
Option
V
H + H1
A)
0' Min.
2' Max.
B)
1' Min.
2' Max
C)
2' Min.
3' Max
D)
3' Min.
4' Max
E)
4' Min.
5' Max
F)
5' Min.
6' Max
G)
6' Min.
7' Max
H)
7' Min.
8' Max
Lengths do not include elbow indicated
|
34
P36E-11 Zero Clearance Direct Vent Gas Fireplace
Elbows
o
elbows.
o
H
V + V1
With these options,
1' Min.
max. total pipe length
2' Min.
is 30 feet with min. of
6 feet total vertical
3' Min.
and max. 8 feet total
horizontal.
4' Min.
5' Min.
Please note min. 1
foot between 90
6' Min.
elbows is required.
elbows, refer to next page.
o
Elbows
o
elbows.
o
V + V1
With these options,
2' Min.
max. total pipe length
3' Min.
is 30 feet with min. of
10 feet total vertical
4' Min.
and max. 8 feet total
horizontal.
6' Min.
7' Min.
Please note min. 1
foot between 90
8' Min.
elbows is required.
9' Min.
10' Min.
V1
o
V1
H1
o
V
H
V
H