8.7 Initial setting 1

Selection of Atmospheric Correction:
By entering ppm value, or by fixing the ppm value to 0
(NIL) not to perform Atmospheric Correction.
1. Selection of Prism Constant: [PRISM CONST.]
Select whether the Prism Constant to be input is set to
0mm, -30mm or to an arbitrary value to be entered from
the keyboard.
2. Selection for Reflector sheet Constant: [SHEET CONST]
Select whether the target constant to be input is set to 0mm,
or to an arbitrary value to be entered from the keyboard.
3. Selection for Refraction & Curvature Corrections
: [CRV/REF CORR]
Select whether the correction factor to be input for both
differences (Refraction, Curvature) is set to 0.14, 0.2 or
none (NIL). Selecting "3. NIL" results in no correction of
both values.
4. Selection of Tilt Compensation: [COMP AXIS]
Select whether Tilt Compensation is to be ON/OFF.
• The factory default for each instrument condition is marked by
8.8 Initial setting 2
1. Selection of the Shot count: [SHOT COUNT]
Select whether the shot count for Shot distance
measurement is to be 1, 3, 5 or an arbitrary count to be
entered.
2. Setting the Shot input: [SHOT INPUT]
Set the shot number for Shot distance measurement.
• The valid range of values for the shot number is from 1 to 99.
• This setting is enabled only when the shot number (Above 2.)
has been set to "4. INPUT".
40
X1.ATM
INPUTaXXX
2.ppm INPUT
3.NIL
X1.-30mmXaXXXXXX
2. 0mm
3.INPUT
X1.
0mmXaXXXXXX
2.INPUT
X1.0.14
XaXXXXXX
2.0.2
3.NIL
X1.ONXXXXXXX
2.OFF
.
X1.1
TIMEXXXXXXX
2.3 TIMES
3.5 TIMES
4.INPUT
01TIMES