• Once set, the Reflector sheet Constant and Prism Constant remain on the measurement
screen as "S 0" or "P 0".
• The factory initial of Reflector sheet Constant and Prism Constant are 0.
• Once set, each Constant remains in memory even after the power is turned off.

7.2 Changing the temperature

The temperature setting can be changed only when "ATM CORR" has been set to "ATM
INPUT" in "initial setting 1".
Example: Setting the temperature to +22°C
Press [F4] [CORR] in MODE B.
(If the instrument is in MODE A,
press [F5] [MODE] to enter MODE B.)
Press [F4] [
] to move the cursor to "3.TEMP"
and press the [F5] [SELECT] to enable the
temperature to be changed.
Clear the exiting values by pressing [F5] [CLEAR].
Input 22 by pressing the numeric keys.
Press the [ENT] key to accept the
temperature to +22°C.
Pressing the [ENT] key returns the instrument to
MODE A.
• The valid range of Temperature input is from -30°C to +60°C.
• When "ATM CORR" in "initial setting 1" has been set to "4. NIL", "*" is displayed to the
left of the temperature value on the correction menu screen. When "*" is on the screen, the
temperature cannot be changed. If "ATM CORR" in "initial setting 1" has been set to "3.
ppm INPUT", no temperature is displayed on the correction menu screen.
• Once set, the temperature is displayed at the centre of the top of the measurement screen.
34