(SELECT:) CONFIG (Configuration) Menu Branch

Use the   keys to move the cursor to the desired choice. Press ENTER. The
function of each CONFIG submenu is as follows:
• OUTPUT Submenu – The selections here allow you to define output
frequency, attenuation, and set Rx operations as ON or OFF.
• REMOTE Submenu – The selections here allow you to select whether you
control the unit locally or remotely; set the unit address; the interface
type, and the operating parameters for that interface.
• REDUNDANCY Submenu – The selections here allow you to identify the
redundancy state and mode (see Appendix A. REDUNDANT SYSTEM
OPERATION for detailed information about redundancy operations).
• FAULTRECOVERY Submenu – The selections here allow you to set the
Fault Recovery operation as AUTO or MANUAL.
• COLDSTART Submenu – The selections here allow you to mute the
converter output signal for a pre-determined time after power is applied
to the converter to ensure that the reference oscillator is stable. (This
submenu is non-operational in redundancy systems.)

6.2.3.1 (CONFIG:) OUTPUT Submenu

On the top line, set the converter Freq (Frequency). You may edit the current
frequency channel from RF
for Model UT-4505/I) in 125 kHz steps (1 kHz steps optional). Use the   keys
to select a digit, and then use the  keys to change that digit.
On the bottom line, set the converter Atten (Attenuation). You may select an
attenuation setting from 0.00 to 25.00 dB in 0.25 dB steps (0.1 dB steps
optional). The default setting is 10.00 dB. Use the   keys to select a digit, and
then use the  keys to change that digit.
OUTPUT
REMOTE
FAULTRECOVERY
COLDSTART
Frq=03627.125 MHz
Atten=19.75 dB
to RF
MHz (e.g.; 05845.000 to 06725.000 MHz
Low
High
6–8
REDUNDANCY
Rx = Off