Status Queries; Rcs (Configuration Status); Rms (Maintenance Status) - Comtech EF Data UT-4500 Series Installation And Operation Manual

C- and ku-band up converters
Hide thumbs Also See for UT-4500 Series:
Table of Contents

Advertisement

UT-4500 Series C- and Ku-Band Up Converters
Serial Interface Operation
8.7.5

Status Queries

Status queries retrieve configuration, maintenance and alarm status in summary
form.
8.7.5.1

RCS (Configuration Status)

Description
Configuration Status:
Confirmation:
If Redundancy=OFF, then xx_yy_z = OFF; otherwise, if Redundancy=ON
and you select a converter as a backup controller: xx_yy_z = BU_yy,
where yy is the number of converters in the chain (i.e. 01 to 12).
Alternately, if Redundancy=ON and you select a converter as a chain
unit, where xx is the converter number (01 to 12), and z = A (if Auto
Mode) or M (if Manual Mode).
8.7.5.2

RMS (Maintenance Status)

Description
Details
Maintenance Status:
<DEV/RMS_{cr}
Confirmation:
>DEV/RMS_{cr}
P15_xx.x{cr}
P14_xx.x{cr}
VCC_x.x{cr}
5VD_x.x{cr}
TEM_xx{cr}
IFL_xx.x{cr}
SUM_xx.x{cr}
COR_xx.x{cr}
FIN_xx.x{cr}{lf}]
Details
<DEV/RCS_{cr}
>DEV/RCS_{cr}
FRE_xxxxx.xxx{cr} Frequency
ATT_yy.yy{cr}
TX_nnn{cr}
ONL_nnn{cr}
RED_xx_yy_z{cr}
CLD_nnn{cr}
AFR_nnn{cr}
EXT_xxx{cr}{lf}]
15V DC Supply
14V DC Supply
VCC Supply
Display 5V DC
Temperature
IFLO Tuning
Sum Loop Tuning
Coarse Loop Tune
Fine Loop Tuning
8–27
Attenuation
Transmitter: ON/OFF/COLD
Online: ON/OFF
See Note
Cold Start: ON/OFF
Auto Flt Recovery: ON/OFF
Ext. Ref.: YES/NO
MN/UT4500.IOM
Revision 3