Admin | Snmp - Comtech EF Data UT-4500 Series Installation And Operation Manual

C- and ku-band up converters
Hide thumbs Also See for UT-4500 Series:
Table of Contents

Advertisement

UT-4500 Series C- and Ku-Band Up Converters
Ethernet Interface Operation

7.5.2.2 Admin | SNMP

Sect. 7.2 SNMP Interface
The Administrator must use this page to manage the SNMP (Simple Network
Management Protocol) settings.
Simple Network Management – Use the drop-down list to set the Simple
Network Management operational setting as Enabled or Disabled.
The Read, Write, and Trap Community Strings can be any combination of
characters and a length of 0 to 20 characters:
• The factory default Read Community String is public.
• The factory default Write Community String is private.
• The factory default Trap Community String is comtech.
SNMP Contact / SNMP Location / SNMP Name – Enter this identity information
in any alphanumeric combination with a length of 0 to 20 characters.
Enable Authentication Trap – Use the drop-down list to set Trap operation as
Enabled or Disabled.
The Administrator can assign up to two Trap IP addresses.
Trap Version – Use the drop-down list to set the Trap Version as SNMPv1 or
SNMPv2.
Figure 7-10. 'Admin | SNMP' Page
7–16
MN/UT4500.IOM
Revision 3