Configuration Commands / Queries; Fre (Frequency); Iff (If Frequency) - Comtech EF Data UT-4500 Series Installation And Operation Manual

C- and ku-band up converters
Hide thumbs Also See for UT-4500 Series:
Table of Contents

Advertisement

UT-4500 Series C- and Ku-Band Up Converters
Serial Interface Operation
8.7.3

Configuration Commands / Queries

8.7.3.1

FRE (Frequency)

Use FRE to set or return the operating frequency. The default RF frequency of
the unit is equal to its minimum operating frequency (RF
Description
Set Frequency:
Confirmation:
Return Frequency:
Confirmation:
8.7.3.2

IFF (IF Frequency)

For units featuring the DUAL IF hardware option: Use IFF to switch the input IF
frequency from 70 MHz to 140 MHz, or from 140 MHz to 70 MHz.
Description
Set Frequency:
Confirmation:
Return Frequency:
Confirmation:
1) The default selection is 70 MHz.
2) The actual IF bandwidth is maintained as the standard ±18 MHz
(±20 MHz) of the 70 MHz configurations.
3) The mute behavior after changing the IF frequency is the same as
the normal mute behavior after changing the RF frequency.
4) You may not "mix" dual IF converters with standard converters
when operating in a redundant system.
Details
<DEV/FRE_xxxxx.xxx{cr} where:
xxxx.xxx = Frequency in MHz (RF
steps optional), dependent upon unit in use.
EXAMPLE: 5845 to 6425 MHz for Model UT-4505 (see Chapter 2.
SPECIFICATIONS for product-specific frequency ranges)
>DEV/FRE_xxxxx.xxx{cr}{lf}]
<DEV/FRE_{cr}
>DEV/FRE_xxxxx.xxx{cr}{lf}]
Details
<DEV/IFF_xxx{cr} where:
xxx = Frequency in MHz, either 140 or 70. No leading zero is required.
>DEV/IFF_xxx{cr}{lf}]
<DEV/IFF_{cr}
>DEV/IFF_xxx{cr}{lf}] where xxx = Frequency in MHz, either 140 or 70. No
leading zero is required.
8–20
MN/UT4500.IOM
).
LOW
to RF
), in 125 kHz steps (1 kHz
LOW
HIGH
Revision 3

Advertisement

Table of Contents
loading