Ethernet Interface Operation
Mute
Use the drop-down list to set the Configuration Mute Mode as On or Off. Click
[Change].
Carrier Mute Mode
Use the drop-down list to set the Carrier Mute Mode as On or Off. Click [Change].
Cold Start Mute
Use the drop-down list to set the Cold Start Mute function as On or Off. Click
[Change].
Fault Recovery
Use the drop-down list to set the Fault Recovery function as MANUAL or
AUTOMATIC. Click [Change].
Channel Slope Adjustment
Enter a slope value (0.0 to 1.0) in 0.1 steps. Click [Change].
Serial
Interface Type – Use the drop-down list to set the operating serial mode as
RS-485 or RS-232.
Remote Address – Enter a valid remote control address from 0001 to 9999.
Baud Rate – Use the drop-down list to set the operating baud rate as 100, 2400,
4800, 9600, 19200 or 38400 baud.
Data bits-Parity-Stop Bits – Use the drop-down list to set the asynchronous
character format as:
• 8-N-1 (8 data bits, no parity, 1 stop bit)
• 7-O-2 (7 data bits, odd parity, 2 stop bits
• 7-E-2 (7 data bits, even parity, 2 stop bits).
Click [Change Serial Configuration].