CHAPTER 4

Planning and Preparing the Site

Before You Install a CTP Platform

CTP150 Environmental Requirements

Copyright © 2015, Juniper Networks, Inc.
Before You Install a CTP Platform on page 17
CTP150 Environmental Requirements on page 17
Before you install a Juniper Networks CTP Circuit to Packet platform:
Verify that the electrical supply meets all power requirements. See the system
specifications for the applicable CTP model.
Verify that the site meets all environment specifications. Refer to the environmental
requirements and the system specifications for the applicable CTP model.
Verify that the cables you plan to use meet the specifications, and review the cabling
recommendations.
Verify the operation of all telephone circuits, digital services, and T1 facilities required
for installation.
Ensure that all IP requirements are met, such as IP addresses, subnet masks, and any
specific routing protocol information.
See the
"CTP150 Platform Specifications" on page 13
specifications.
Choose a location for the device that is dry, relatively dust free, well ventilated, and air
conditioned. If you install equipment in a rack, be sure that the floor is capable of
supporting the combined weight of the rack and the installed equipment. Place the device
in a location with sufficient access to power and network cables.
Like other network devices, the device generates a significant amount of heat. You must
provide a balanced environment so that the device performs properly and safely. See
the individual system specifications for acceptable ranges of temperature and humidity.
Be sure to allow enough space around the device for adequate ventilation. Inadequate
ventilation can cause the device to overheat.
for complete environmental
17