Table 8. SAN192C-6 Crossbar Modules LEDs
LED
Status
Locater ID
The crossbar fabric switching modules are located behind the fan modules in the chassis, the LEDs on
the crossbar fabric switching module are not easily visible from the back of the chassis. So, the crossbar
fabric switching module status LEDs are provided on the fan modules as well. Each fan module covers two
crossbar fabric switching modules, the status LEDs for two crossbar fabric modules are present on each
fan module. If the fan module is removed, the status and locator LEDs on the crossbar fabric switching
modules will be visible.
When a crossbar fabric switching module needs to be located, the locator LED of the corresponding fan
module must be activated, followed by the locator LED of fabric module, using the CLIs locator-led
fan <fan module number> and locator-led xbar <xbar slot number>. For example, to
Status
Green
Orange
Blinking Red
Red
Off
Blinking Blue
Off
Chapter 1. Introducing the IBM c-type SAN Directors  31
Description
All diagnostics pass. The
module is operational (normal
initialization sequence).
One of the following occurs:
The module is booting or running
diagnostics (normal initialization
sequence).
An over-temperature condition
occurred (a minor threshold was
exceeded during environmental
monitoring).
One of the following occurs:
The diagnostic test failed.
The module is not operational
because a fault occurred during
the initialization sequence.
An over-temperature condition
occurred (a major threshold was
exceeded during environmental
monitoring).
Fabric module has been manually
powered off.
Bad slot ID parity.
The module is not receiving
power.
Operator has flagged this card for
identification.
Operator has not flagged this
card for identification.