IBM SAN192C-6 Installation, Service And User Manual page 115

Hide thumbs Also See for SAN192C-6:
Table of Contents

Advertisement

Migration process is complete now. Supervisor-3 in standby slot
can now be replaced with Supervisor-4.
2019 Jun 25 15:18:00 switch %SYSMGR-2-SBY_SUP_LESS_MEMORY_SLOT:
Supervisor in slot 6 is
running with less memory than active supervisor in slot 5
2019 Jun 25 15:18:00 switch %SYSMGR-2-CONVERT_STARTUP_ABORTED:
Conversion of startup-config failed.
2019 Jun 25 15:18:00 switch %PLATFORM-2-MOD_PWRDN:
Module 6 powered down (Serial number JAE17440HVB)
2019 Jun 25 15:18:00 switch %PLATFORM-5-MOD_STATUS:
Module 6 current-status is MOD_STATUS_CONFIGPOWERED_DOWN
2019 Jun 25 15:18:00 switch %PLATFORM-5-MOD_STATUS:
Module 6 current-status is MOD_STATUS_POWERED_DOWN
2019 Jun 25 15:18:00 switch %PLATFORM-2-MOD_REMOVE:
Module 6 removed (Serial number JAE17440HVB)
Note : The old active Supervisor-1 Module will be powered down. The supervisor Status LED will be
blinking red, when the supervisor module is powered down by the migration command. If the Status
LED is not blinking red, then check the migration status using the show logging onboard migration
status command on any management session.
10. After the successful completion of the system switchover, the following syslog message is displayed:
2019 Jun 25 15:18:0 switch %BOOTVAR-2-SUP_MIGRATION_CONFIG_COMPLETE:
Migration process is complete now. Supervisor-3 in standby slot can now be
replaced with Supervisor-4.
Warning A mix of different Supervisor-4 Modules and
Supervisor-1 Modules outside a maintenance window is
not supported.
This mix of modules is supported only while you are migrating
from a Supervisor-1
Module to a Supervisor-4 Module.
11. After the switchover to the Supervisor-4 Module is completed, the boot parameters are set for the
supervisor migration process.
Do not set any configuration parameters until the boot parameters are set. After the boot parameters
are set, the migration process is complete. Use the show boot command to display the current boot
variables and the show module command to display the modules installed in the switch.
Supervisor-4 module outputs
switch# show boot
kickstart variable = bootflash:/m9700-sf4ek9-kickstart-mz.8.4.1.bin
system variable = bootflash:/m9700-sf4ek9-mz.8.4.1.bin
Boot POAP Disabled
switch# show module
Mod Ports
Module-Type
--- -----
-----------------------------------
1
48
1/10 Gbps Ethernet Module
2
48
2/4/8/10/16 Gbps Advanced FC Module
3
24
40 Gbps FCoE Module
4
48
4/8/16/32 Gbps Advanced FC Module
5
0
Supervisor Module-4
6
0
Supervisor Module-3
7
34
1/10/40G IPS,2/4/8/10/16G FC Module
8
48
4/8/16/32 Gbps Advanced FC Module
10
48
2/4/8/10/16 Gbps Advanced FC Module
Mod
Power-Status
---
------------
6
powered-dn
Mod
Sw
---
------
1
8.4(1)
2
8.4(1)
3
8.4(1)
4
8.4(1)
5
8.4(1)
6
8.4(1)
7
8.4(1)
8
8.4(1)
10
8.4(1)
Reason
---------------------------
Policy trigger initiated reset:
Stdby has lower mem than active
Hw
---------
1.1
1.3
1.0
1.0
1.0
1.1
1.0
1.0
1.1
Model
-----------------
DS-X9848-480K9
DS-X9448-768K9
DS-X9824-960K9
DS-X9648-1536K9
DS-X97-SF4-K9
DS-X97-SF1-K9
DS-X9334-K9
DS-X9648-1536K9
DS-X9448-768K9
Chapter 3. Installing the IBM c-type SAN Device  89