Ibm Supervisor-1E Module Leds - IBM SAN192C-6 Installation, Service And User Manual

Hide thumbs Also See for SAN192C-6:
Table of Contents

Advertisement

14. Status: system diagnostic test status LED
15. System: system environment status LED
16. Active: supervisor redundancy status LED
17. PWR MGMT: system power status LED
18. Management port operational status LED
19. Module ejection lever
20. Slot0 USB port
Table 4 on page 18 describes the LEDs on the IBM c-type SAN Supervisor-1E Module.
Table 4. IBM Supervisor-1E Module LEDs
LED
ID
Status
18  IBM Storage Networking SAN192C-6, SAN384C-6 and SAN768C-6: SAN192C-6, SAN384C-6 and
SAN768C-6 Installation, Service, and User Guide
Status
Flashing blue
Off
Green
Red
Flashing Red
Off
Description
A user has activated this LED
to allow a person to find this
module in the chassis.
Location identification is
deactivated for this module.
All module diagnostics passed.
The module is operational.
The module has detected an
error and cannot power on or
boot up.
The module is not properly
inserted.
A bootup or runtime diagnostic
test has failed.
Indicates one of the following
conditions:
The temperature of the
module has exceeded the safe
operating temperature limits (a
major temperature alarm has
occurred). The module has been
shut down to prevent permanent
damage. The system will be shut
down after two minutes if this
condition is not cleared.
The module is resetting.
The ejector lever is open.
The module is not receiving
power.