Group 6 Protection Parameters - Delta Electronics Elevator Drive VFD-VL User Manual

Elevator drive
Table of Contents

Advertisement

Group 6 Protection Parameters

Pr.
Explanation
Low Voltage Level
06-00
Phase-loss Protection
06-01
Over-current Stall
06-02
Prevention during
Acceleration
Over-current Stall
06-03
Prevention during Operation
Accel./Decel. Time Selection
06-04
of Stall Prevention at
constant speed
Over-torque Detection
06-05
Selection (OT1)
Over-torque Detection Level
06-06
(OT1)
Over-torque Detection Time
06-07
(OT1)
Over-torque Detection
06-08
Selection (OT2)
Over-torque Detection Level
06-09
(OT2)
Over-torque Detection Time
06-10
(OT2)
Current Limit
06-11
Electronic Thermal Relay
06-12
Selection
Electronic Thermal
06-13
Characteristic
Heat Sink Over-heat (OH)
06-14
Warning
Stall Prevention Limit Level
06-15
06-16
Present Fault Record
06-17
Second Most Recent Fault
Record
06-18
Third Most Recent Fault
Record
06-19
Fourth Most Recent Fault
Record
06-20
Fifth Most Recent Fault
Record
06-21
Sixth Most Recent Fault
Record
Revision Nov. 2008, VLE1, SW V1.03
Settings
160.0~220.0Vdc
320.0~440.0Vdc
0: Warn and keep operation
1: Warn and ramp to stop
2: Warn and coast to stop
00: disable
00~250%
00: disable
00~250%
0: by current accel/decel time
1: by the 1st accel/decel time
2: by the 2nd accel/decel time
3: by the 3rd accel/decel time
4: by the 4th accel/decel time
5: by auto accel/decel time
0: disable
1: over-torque detection during constant speed operation,
continue to operate after detection
2: over-torque detection during constant speed operation, stop
operation after detection
3: over-torque detection during operation, continue to operate
after detection
4: over-torque detection during operation, stop operation after
detection
10~250%
0.0~60.0 sec
0: disable
1: over-torque detection during constant speed operation,
continue to operate after detection
2: over-torque detection during constant speed operation, stop
operation after detection
3: over-torque detection during operation, continue to operate
after detection
4: over-torque detection during operation, stop operation after
detection
10~250%
0.0~60.0 sec
0~250%
0: Inverter motor
1: Standard motor
2: Disable
30.0~600.0 sec
0.0~110.0℃
0~100% (refer to Pr.06-02, Pr.06-03)
0: No fault
1: Over-current during acceleration (ocA)
2: Over-current during deceleration (ocd)
3: Over-current during constant speed (ocn)
4: Ground fault (GFF)
5: IGBT short-circuit (occ)
6: Over-current at stop (ocS)
7: Over-voltage during acceleration (ovA)
8: Over-voltage during deceleration (ovd)
9: Over-voltage during constant speed (ovn)
10: Over-voltage at stop (ovS)
Chapter 4 Parameters|
Factory
Setting
180.0
○ ○ ○ ○ ○ ○
360.0
○ ○ ○ ○ ○ ○
2
○ ○ ○ ○ ○ ○
00
○ ○ ○
00
○ ○ ○
0
○ ○ ○
0
○ ○ ○ ○ ○ ○
150
○ ○ ○ ○ ○ ○
0.1
○ ○ ○ ○ ○ ○
0
○ ○ ○ ○ ○ ○
150
○ ○ ○ ○ ○ ○
0.1
○ ○ ○ ○ ○ ○
150
2
○ ○ ○ ○ ○ ○
60.0
○ ○ ○ ○ ○ ○
85.0
○ ○ ○ ○ ○ ○
50
○ ○ ○
0
○ ○ ○ ○ ○ ○
0
○ ○ ○ ○ ○ ○
0
○ ○ ○ ○ ○ ○
0
○ ○ ○ ○ ○ ○
0
○ ○ ○ ○ ○ ○
0
○ ○ ○ ○ ○ ○
○ ○
4-11