00-02
Parameter Reset
Control
VF
VFPG
mode
Settings
When it is set to 1, all parameters are read only except Pr.00-00~00-07 and it can be used
with password setting for password protection.
This parameter allows the user to reset all parameters to the factory settings except the fault
records (Pr.06-16 ~ Pr.06-21).
50Hz: Pr.01-01 is set to 50Hz and Pr.01-02 is set to 230V or 400V.
60Hz: Pr.01-01 is set to 60Hz and Pr.01-02 is set to 230Vor 460V.
When Pr.00-02=08, the KPVL-CC01 keypad is locked and only Pr.00-02 can be set. To unlock
the keypad, set Pr.00-02=00.
When Pr.00-02 is set to 1, Pr.00-02 setting should be set to 0 before setting to other setting.
Start-up Display Selection
00-03
Control
VF
VFPG
mode
Settings 0
1
2
3
4
5
This parameter determines the start-up display page after power is applied to the drive.
00-04
Content of Multi-Function Display
Control
VF
VFPG
mode
Settings
Revision Nov. 2008, VLE1, SW V1.03
SVC
FOCPG TQCPG FOCPM
0
No Function
1
Read Only
8
Keypad Lock
9
All parameters are reset to factory settings (50Hz, 220V/380V)
10 All parameters are reset to factory settings (60Hz, 220V/440V)
SVC
FOCPG TQCPG FOCPM
Display the frequency command value. (LED F)
Display the actual output frequency (LED H)
DC BUS voltage
Display the output current (A)
Output voltage
Multifunction display, see Pr.00-04
SVC
FOCPG TQCPG FOCPM
0 Display the output current in A supplied to the motor
1 Reserved
Chapter 4 Parameters|
Factory setting: 0
Factory setting: 0
Factory setting: 0
U:
O
u t
p
u t
E
SE
E
EE
E
EE
0
Cu r
r
e n
t
. 0 m
A
ps
E
4-21