Delta Electronics Elevator Drive VFD-VL User Manual page 67

Elevator drive
Table of Contents

Advertisement

Chapter 4 Parameters|
Pr.
Explanation
Fault Output Option 1
06-22
Fault Output Option 2
06-23
Fault Output Option 3
06-24
Fault Output Option 4
06-25
PTC (Positive Temperature
06-26
Coefficient) Detection
Selection
PTC Level
06-27
Filter Time for PTC
06-28
Detection
06-29
EPS Voltage
Setting Method of Fault
06-30
Output
4-12
Settings
11: Low-voltage during acceleration (LvA)
12: Low-voltage during deceleration (Lvd)
13: Low-voltage during constant speed (Lvn)
14: Low-voltage at stop (LvS)
15: Phase loss (PHL)
16: IGBT heat sink over-heat (oH1)
17: Heat sink over-heat (oH2)(for 40HP above)
18: TH1 open loop error (tH1o)
19: TH2 open loop error (tH2o)
20: Fan error signal output
21: over-load (oL) (150% 1Min)
22: Motor over-load (EoL1)
23: Reserved
24: Motor PTC overheat (oH3)
25: Reserved
26: over-torque 1 (ot1)
27: over-torque 1 (ot2)
28: Reserved
29: Reserved
30: Memory write-in error (cF1)
31: Memory read-out error (cF2)
32: Isum current detection error (cd0)
33: U-phase current detection error (cd1)
34: V-phase current detection error (cd2)
35: W-phase current detection error (cd3)
36: Clamp current detection error (Hd0)
37: Over-current detection error (Hd1)
38: Over-voltage detection error (Hd2)
39: Ground current detection error (Hd3)
40: Auto tuning error (AuE)
41: PID feedback loss (AFE)
42: PG feedback error (PGF1)
43: PG feedback loss (PGF2)
44: PG feedback stall (PGF3)
45: PG slip error (PGF4)
46: PG ref input error (PGr1)
47: PG ref loss (PGr2)
48: Analog current input error (ACE)
49: External fault input (EF)
50: Emergency stop (EF1)
51: Reserved
52: Password error (PcodE)
53: Reserved
54: Communication error (cE1)
55: Communication error (cE2)
56: Communication error (cE3)
57: Communication error (cE4)
58: Communication Time-out (cE10)
59: PU time-out (cP10)
60: Brake chopper error (bF)
61-62: Reserved
63: Safety loop error (Sry)
64: Mechanical brake error (MBF)
65: PGF5 hardware error
0~65535 (refer to bit table for fault code)
0~65535 (refer to bit table for fault code)
0~65535 (refer to bit table for fault code)
0~65535 (refer to bit table for fault code)
0: Warn and keep operation
1: Warn and ramp to stop
0.0~100.0%
0.00~10.00sec
48.0~375.0Vdc
96.0~750.0Vdc
0: By settings of Pr.06-22~06-25
1: By the binary setting
Factory
Setting
0
○ ○ ○ ○ ○ ○
0
○ ○ ○ ○ ○ ○
0
○ ○ ○ ○ ○ ○
0
○ ○ ○ ○ ○ ○
0
○ ○ ○ ○ ○ ○
50.0
○ ○ ○ ○ ○ ○
0.20
○ ○ ○ ○ ○ ○
48.0
○ ○ ○ ○ ○ ○
96.0
0
○ ○ ○ ○ ○ ○
Revision Nov. 2008, VLE1, SW V1.03

Hide quick links:

Advertisement

Table of Contents
loading