Control System
Start Torque
Speed Control Range
Speed Control Resolution
Speed Response Ability
Max. Output Frequency
Output Frequency Accuracy
Frequency Setting
Resolution
Torque Limit
Torque Accuracy
Accel/Decel Time
V/f Curve
Frequency Setting Signal
Brake Torque
Motor Protection
Over-current Protection
Ground Leakage Current
Protection
Overload Ability
Over-voltage Protection
Over-voltage Protection for
the Input Power
Over-temperature Protection
Compensation for the
Momentory Power Loss
Protection Level
Operation Temperature
Storage Temperature
Ambient Humidity
Vibration
Installation Location
Approvals
Revision Nov. 2008, VLE1, SW V1.03
General Specifications
1: V/f, 2: VF+PG, 3: SVC, 4: FOC+PG, 5: TQR+PG, 6:FOC+PM
Starting torque is 150% at 0.5Hz and 0Hz with control modes FOC + PG and
FOC+PM
1:100 Sensorless vector (up to 1:1000 when using PG card)
±0.5% Sensorless vector (up to±0.02% when using PG card)
5Hz (up to 30Hz for vector control)
0.00 to 120.00Hz
Digital command ±0.005%, analog command ±0.5%
Digital command ±0.01Hz, analog command: 1/4096(12-bit) of the max. output
frequency
Max. is 200% torque current
±5%
0.00 to 600.00/0.0 to 6000.0 seconds
Adjustable V/f curve using 4 independent points and square curve
0-+10V, ±10V, 4~20mA
About 20%
Electronic thermal relay protection
The current forces 220% of the over-current protection and 300% of the rated
current
Higher than 50% rated current
Constant torque: 150% for 60 seconds, variable torque: 200% for 3 seconds
Over-voltage level: Vdc > 400/800V; low-voltage level: Vdc < 200/400V
Varistor (MOV)
Built-in temperature sensor
Up to 5 seconds for parameter setting
NEMA 1/IP20
-10°C to 45°C
-20°C to 60°C
Below 90% RH (non-condensing)
2
9.80665m/s
(1G) less than 20Hz, 5.88m/s
Altitude 1,000 m or lower, keep from corrosive gasses, liquid and dust
Appendix A Specifications|
2
(0.6G) at 20 to 50Hz
A-3