Setting 8: To increase torque and control speed precisely. (1:1000). This setting is only for
using with permanent magnet motor and others are for induction motor.
00-10
Reserved
00-11
Reserved
00-12
Carrier Frequency
Control
VF
VFPG
mode
Settings
This parameter determinates the PWM carrier frequency of the AC motor drive.
Models
Setting Range
Factory Setting
Frequency
From the table, we see that the PWM carrier frequency has a significant influence on the
electromagnetic noise, AC motor drive heat dissipation, and motor acoustic noise.
00-13
Auto Voltage Regulation (AVR) Function
Control
VF
VFPG
mode
Settings
It is used to select the AVR mode. AVR is used to regulate the output voltage to the motor. For
example, if V/f curve is set to AC200V/50Hz and the input voltage is from 200 to 264VAC, the
output voltage won't excess AC200V/50Hz. If the input voltage is from 180 to 200V, the output
voltage to the motor and the input voltage will be in direct proportion.
When setting Pr.00-13 to 1 during ramp to stop and used with auto accel./decel. function, the
acceleration will be smoother and faster.
Revision Nov. 2008, VLE1, SW V1.03
SVC
FOCPG TQCPG FOCPM
2~15KHz
7.5-15HP
5.5-11kW
2~15kHz
12kHz
Carrier
Acoustic
Noise
Significant
2kH z
8kH z
15kHz
Minimal
SVC
FOCPG TQCPG FOCPM
0
Enable AVR
1
Disable AVR
2
Disable AVR when deceleration stop
230V/460V Series
20-30HP
15-22kW
2~15kHz
02-09kHz
9kHz
Electromagnetic
Heat
Noise or Leakage
Dissipation
Current
Minimal
Minimal
Significant
Significant
Chapter 4 Parameters|
Factory setting: 12
40-60 HP
40-100HP
30-45kW
30-75kW
02~15kHz
6kHz
6kHz
Current
Wave
Factory setting: 0
Unit: 1
4-27