Delta Electronics Elevator Drive VFD-VL User Manual page 104

Elevator drive
Table of Contents

Advertisement

MI1=40
Enable dr ive
function
Start for war d
running/start
rev er se running
MI2=1
multi-s tep
speed1
MI3=2
multi-s tep
speed2
MI4=3
multi-s tep
speed3
frequency
output
DC brak e
multi-function
output =15
Motor-c ontr olled
magneti c
contactor output
multi-function
output=1
operation
indication
multi-function
output=12
mechanical
02-29 br ake r elease delay time
brake release
w hen elevator starts
11-00 bit 7=1
Z er o speed
control
elevator starts running
2
electrom agnetic valve is ON
brake release
3
the end of D C brake time
4
at start-up
Revision Nov. 2008, VLE1, SW V1.03
2
4
1
1
0
01-25=S2
01-12
accel. time
01-24=S1
07-03
D C brak e time duri ng start-up
02-31
Turn on delay of magnetic
contactor betw een dri ve and
motor
3
10-22
Oper ation ti me of z er o speed
start deceleration
5
6
the end of creep
7
start DC brake time during s topping
the end of D C brake time during stopping
8
Chapter 4 Parameters|
5
6
0
0
1
0
0
0
01=26=S3
01-13
decel. time
01-27=S4
01-30=S5
02-32
Turn off delay of magnetic
contactor between dri ve and
motor
motor releas e
9
7
8
9
01-29
Switch fr equency
for S3/S 4 changes
to S5
01-31
Deceleration time
when operating
without RU N command
07-04
D C brak e time
during stoppi ng
02-30
brake engage delay time
when elevator stops
4-49

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents