Terminal
Symbol
Multi-function Output 1
MO1
(Photocoupler)
Multi-function Output 2
MO2
(Photocoupler)
Analog current Input
ACI
Auxiliary analog voltage input
AUI1/
AUI2
Analog control signal
ACM
(common)
*Control signal wiring size: 18 AWG (0.75 mm
Analog input terminals (ACI, AUI1, AUI2, ACM)
2-12
Terminal Function
ACI circuit
ACI
ACM
internal circuit
+10 V
AUI ci rcu it
|
-1 0V
AUI
ACM
in ter na l ci rcu it
Factory Settings (SINK)
ON: Connect to DCM
The AC motor drive output every monitor signal,
such as operational, frequency attained,
overload, etc. by open collector transistor. Refer
to Pr.03.01 multi-function output terminals for
details.
internal circuit
MCM
Impedance:
250Ω
Resolution:
12 bits
Range:
4 ~ 20mA/0~10V =
0 ~ Max. Output Frequency
(Pr.01-00)
Set-up:
Pr.03-00 ~ Pr.03-02
Impedance:
2mΩ
Resolution:
12 bits
Range:
-10 ~ +10VDC =
0 ~ Max. Output Frequency
(Pr.01-00)
Set-up:
Pr.03-00 ~ Pr.03-02
Common for ACI, AUI1, AUI2
2
) with shielded wire.
Max: 48Vdc/50m A