Chapter 4 Parameters|

4.1 Summary of Parameter Settings

: The parameter can be set during operation.
Group 0 System Parameters
Explanation
Pr.
Identity Code of the AC
00-00
motor drive
Rated Current Display of the
00-01
AC motor drive
Parameter Reset
00-02
00-03 Start-up Display Selection
Content of Multi Function
00-04
Display
00-05 User-Defined Coefficient K
Software Version
00-06
00-07 Password Input
00-08 Password Set
Control Method
00-09
Reserved
00-10
Reserved
00-11
00-12 Carrier Frequency
4-2
Settings
Read-only
Read-only
0: No function
1: Read only
8: Keypad lock
9: All parameters are reset to factory settings (50Hz,
220V/380V)
10: All parameters are reset to factory settings (60Hz,
220V/440V)
0: Display the frequency command value (LED F)
1: Display the actual output frequency (LED H)
2: DC BUS voltage
3: Display the output current (A)
4: Output voltage
5: Multifunction display, see Pr.00-04
0: Display output current (A)
1: Reserved
2: Display output frequency (H)
3: Display DC-BUS voltage (U)
4: Display output voltage (E)
5: Output power factor angle (n)
6: Display output power kW(P)
7: Display actual motor speed in rpm(r)
8: Display estimate output torque kg-m (t)
9: Display PG position (G)
10: Reserved
11: Display AUI1 % (1.)
12: Display ACI % (2.)
13: Display AUI2 % (3.)
14: Display the temperature of heat sink (°C)
15: Display the temperature of IGBT °C (T.)
16: The status of digital input ON/OFF (i)
17: The status of digital output ON/OFF (o)
18: Multi-step speed (S)
19: The corresponding CPU pin status of digital input (i.)
20: The corresponding CPU pin status of digital output (o.)
21-23: Reserved
24: Output AC voltage when malfunction (8)
25: Output DC voltage when malfunction (8.)
26: Output frequency when malfunction (h)
27: Output current when malfunction (4)
28: Output frequency command when malfunction (h.)
Digit 4: decimal point number (0 to 3)
Digit 0-3: 40 to 9999
Read-only
1 to 9998 and 10000 to 65535
0 to 2: times of wrong password
1 to 9998 and 10000 to 65535
0: No password set or successful input in Pr.00-07
1: Password has been set
0: V/f Control
1: V/f Control + Encoder (VFPG)
2: Sensorless vector control (SVC)
3: FOC vector control + Encoder (FOCPG)
4: Torque control + Encoder (TQCPG)
8: FOC PM control (FOCPM)
2~15KHz
Factory
Setting
#
○ ○ ○ ○ ○ ○
#
○ ○ ○ ○ ○ ○
0
○ ○ ○ ○ ○ ○
0
○ ○ ○ ○ ○ ○
0
○ ○ ○ ○ ○ ○
0
○ ○ ○ ○ ○ ○
#.#
○ ○ ○ ○ ○ ○
0
○ ○ ○ ○ ○ ○
0
○ ○ ○ ○ ○ ○
0
○ ○ ○ ○ ○ ○
12
○ ○ ○ ○ ○ ○
Revision Nov. 2008, VLE1, SW V1.03