Run
1
2
4
Table 5 – Kindling and Start-up Fuel Description Summary
Note: Test 3 was a high burn used to create a coal bed for test number 4, no particulate sampling
occurred during this test.
Table 6 – Fuel Measurement and Cordwood Description Summary – TEST
Test Fuel
Wet Basis
Run
(lbs)
1
19.7
2
23.4
3
19.9
4
23.8
Table 4 – Test Facility Conditions
Room Temperature
(°F)
Before
After
66
75
74
80
71
85
Maple Cordwood
Kindling
Weight
Wet Basis
Run
(lbs)
1
3.8
3
3.90
Maple Cordwood
Firebox
Fuel Loading
Volume
Density Wet
3
(ft
)
Basis
3
(lbs/ft
)
2.03
9.7
2.03
11.5
2.03
9.8
2.03
11.7
8 of 236
Barometric Pressure
(Hg)
Before
After
30.05
29.96
30.05
29.96
30.06
29.94
Start-up
Residual
Fuel Weight
Start-up
Wet Basis
fuel weight
(lbs)
(lbs)
5.8
2.1
5.7
2.1
Test Fuel
Dry Basis
(lbs)
23.45
18.97
24.73
19.74
Air Velocity
(ft/min)
Before
After
<50
<50
<50
Test Fuel
Consumed
During Test
Piece
Dry Basis (lbs)
Length
(in)
3@14
20.3
2@16
4@14
18.8
2@16
3@14
20.5
2@16
4@14
19.7
2@16
<50
<50
<50

Advertisement