Travis Industries Medium Flush Wood Hybrid Fyre Insert Manual page 71

Table of Contents

Advertisement

OMNI-Test Laboratories, Inc.
Run:
2
Manufacturer:
Travis Industries
Model:
Medium Flushwood
Tracking No.:
2301
Project No.:
0028WN118E
Test Date:
31-Jul-18
Beginning Clock Time:
11:30
Meter Box Y Factor:
0.983
(1)
0.974
Barometric Pressure:
Begin
Middle
End
Export to
30.05
29.96
OMNI Equipment Numbers:
Gas
Gas
Orifice
Sample
Sample
Elapsed
Meter 1
Meter 2
dH 1
Rate 1
Rate 2
Time (min)
3
3
O)
)
)
(cfm)
(cfm)
("H
(ft
(ft
2
350
57.689
60.908
0.17
0.18
2.26
360
59.369
62.681
0.17
0.18
2.26
370
61.050
64.457
0.17
0.18
2.28
380
62.730
66.234
0.17
0.18
2.26
390
64.407
68.011
0.17
0.18
2.25
400
66.086
69.789
0.17
0.18
2.25
410
67.763
71.569
0.17
0.18
2.25
420
69.440
73.349
0.17
0.18
2.26
430
71.118
75.130
0.17
0.18
2.25
440
72.795
76.911
0.17
0.18
2.27
450
74.305
78.694
0.15
0.18
2.27
460
76.151
80.476
0.18
0.18
2.25
470
77.829
82.260
0.17
0.18
2.26
480
79.509
84.043
0.17
0.18
2.26
490
81.187
85.828
0.17
0.18
2.26
500
82.866
87.609
0.17
0.18
2.25
510
84.545
89.391
0.17
0.18
2.26
520
86.223
91.172
0.17
0.18
2.26
530
87.900
92.952
0.17
0.18
2.25
540
89.577
94.732
0.17
0.18
2.26
550
91.255
96.513
0.17
0.18
2.26
Avg/Tot
91.255
96.513
0.17
0.18
2.22
Control No. P-SSAR-0003
Total Sampling Time:
550
min
Recording Interval:
10
min
Background Sample Volume:
cubic feet
(2)
(Amb)
Average
30.01 0
Particulate Sampling Data
Orifice
Meter 1
Meter 1
Meter 2
Dilution
Meter 2
Dilution
dH 2
Temp
Vacuum
Vacuum
Tunnel
Temp (°F)
Tunnel (°F)
O)
(°F)
("Hg)
("H
("Hg)
Center dP
2
93
-0.71
60.91
60.908
60.908
97
0.060
93
-0.99
62.68
62.681
62.681
96
0.060
93
-0.65
64.46
64.457
64.457
96
0.050
93
-0.75
66.23
66.234
66.234
96
0.050
93
-0.89
68.01
68.011
68.011
96
0.050
94
-1
69.79
69.789
69.789
96
0.050
94
-0.97
71.57
71.569
71.569
95
0.050
94
-0.84
73.35
73.349
73.349
95
0.050
94
-0.68
75.13
75.13
75.13
95
0.050
94
-0.82
76.91
76.911
76.911
95
0.050
94
-0.65
78.69
78.694
78.694
94
0.050
94
-0.66
80.48
80.476
80.476
94
0.050
94
-0.66
82.26
82.26
82.26
93
0.050
93
-0.97
84.04
84.043
84.043
93
0.050
93
-0.96
85.83
85.828
85.828
92
0.050
92
-0.8
87.61
87.609
87.609
91
0.050
92
-0.81
89.39
89.391
89.391
90
0.050
91
-0.66
91.17
91.172
91.172
89
0.050
91
-0.7
92.95
92.952
92.952
89
0.050
90
-0.99
94.73
94.732
94.732
88
0.050
90
-0.65
96.51
96.513
96.513
87
0.050
90
47.93
48
99
0.053
Wood Heater Test Data
Emissions and Efficiency Data
PM Control Modules:
371, 372
Dilution Tunnel MW(dry):
29.00 lb/lb-mole
Avg. Tunnel Velocity:
Dilution Tunnel MW(wet):
28.78 lb/lb-mole
Initial Tunnel Flow:
Dilution Tunnel H2O:
2.00 percent
Average Tunnel Flow:
Dilution Tunnel Static:
-0.210
"H2O
Post-Test Leak Check (1):
Tunnel Area:
0.19635
ft2
Post-Test Leak Check (2):
Pitot Tube Cp:
0.99
Average Test Piece Fuel Moisture:
Velocity Traverse Data
Pt.1
Pt.2
Pt.3
Pt.4
Pt.5
Initial dP
0.060
0.074
0.080
0.070
0.060
0.080
Temp:
113
113
113
113
112
V
ft/sec
V
18.57
19.47
strav
scent
Fuel Weight (lb)
Pro. Rate
Pro. Rate
Scale
Weight
Firebox
Firebox
Firebox Top
1
2
Reading
Change
Bottom
Back
94
92
1.0
-0.1
333
122
94
92
0.9
-0.1
329
121
103
100
0.8
-0.1
322
120
103
100
0.7
-0.1
315
119
103
100
0.6
-0.1
307
119
103
99
0.5
-0.1
302
118
103
99
0.4
-0.1
296
118
103
99
0.3
-0.1
288
117
103
99
0.3
0
280
116
103
98
0.2
-0.1
270
116
92
98
0.2
0
264
115
113
98
0.1
-0.1
262
115
103
97
0.1
0
254
115
103
97
0.1
-0.03
247
114
103
97
0.1
-0.01
240
113
103
96
0.1
-0.01
232
112
103
96
0.0
-0.01
222
112
103
95
0.0
-0.01
212
111
103
95
0.0
-0.01
201
110
103
94
0.0
-0.01
191
110
103
94
0.0
-0.01
181
108
100
100
Page 4 of 7
71 of 236
14.91
ft/sec.
197.1
scfm
163.0
scfm
0.000
cfm @
8
in. Hg
0.000
cfm @
6
in. Hg
23.11
Dry Basis %
Pt.6
Pt.7
Pt.8
Center
0.078
0.074
0.080
"H2O
112
112
112
112
°F
ft/sec
F
0.954
p
Temperature Data (°F)
Firebox
Avg. Stove
Catalyst
Firebox Left
Stack
Filter 1
Right
Surface
Exit
167
299
272
239
398
181
86
165
292
267
235
394
178
86
163
284
262
230
384
176
86
160
278
255
225
374
172
86
159
272
249
221
366
169
86
157
266
244
217
358
166
86
155
261
238
214
350
162
85
154
256
232
209
343
159
85
152
250
226
205
332
156
85
150
242
220
200
320
153
85
148
234
213
195
310
149
85
148
234
213
194
309
149
85
146
226
207
190
300
145
85
144
219
201
185
290
141
85
142
213
196
181
280
136
85
140
206
191
176
266
132
85
137
199
185
171
246
127
84
135
192
179
166
227
119
85
133
185
173
160
212
112
84
131
177
167
155
200
106
84
128
170
161
150
190
101
84
220.4
Technician Signature:________________________________
Stack Gas Data
Draft
Dryer
Dryer
CO
CO
2
Filter 2
Ambient
O)
Exit 1
Exit 2
("H
(%)
(%)
2
79
87
80
87
-0.024
6.52
-0.01
80
87
80
86
-0.023
6.44
-0.01
71
87
67
87
-0.021
6.11
-0.01
68
87
62
88
-0.021
6.13
-0.01
66
87
62
88
-0.021
5.97
-0.01
66
87
62
89
-0.020
5.96
-0.01
66
86
63
87
-0.020
5.88
-0.01
67
86
65
88
-0.019
5.71
-0.01
68
86
66
88
-0.019
5.4
-0.01
69
86
68
87
-0.018
4.97
-0.01
69
86
70
87
-0.017
5.01
-0.01
69
86
71
87
-0.017
5.03
-0.01
70
85
72
87
-0.016
5.01
-0.01
71
85
73
86
-0.015
4.96
-0.01
72
85
74
86
-0.013
4.69
0.04
73
85
74
86
-0.012
4.3
0.23
73
85
75
85
-0.011
3.88
0.51
74
85
75
84
-0.010
3.91
0.69
74
84
75
83
-0.008
4.05
0.73
75
84
75
81
-0.006
4.26
0.76
75
83
76
80
-0.005
4.3
0.75
73
86
72
84
-0.038
Run 2-Low_10-min

Advertisement

Table of Contents
loading

Table of Contents