DIFFERENTIAL PRESSURE GAUGE CALIBRATION DATA SHEET
Instrument to be calibrated: Pressure Transducer______________
Maximum Range: 0-2" WC
Calibration Instrument: Digital Manometer
Date: 7/16/18
This form is to be used only in conjunction with Standard Procedure C-SPC.
Range of
Calibration Point
("WC)
0-20% Max. Range
0 - 0.4
20-40% Max. Range
0.4 - 0.8
40-60% Max. Range
0.8 – 1.2
60-80% Max. Range
1.2 – 1.6
80-100% Max. Range
1.6 – 2.0
*Acceptable tolerance is 4%.
The uncertainty of measurement is ±0.4" WC. This is based on the reference standard having a TAR (Test
Accuracy Ratio) of at least 4:1.
Technician signature:
Reviewed by:
ID Number: OMNI-00372
By:
B. Davis
Digital
Pressure Gauge
Manometer
Response
Input
("WC)
0.037
0.512
1.169
1.540
1.772
167 of 236
ID Number: OMNI-00395
Difference
(Input -
("WC)
Response)
0.042
0.005
0.509
0.003
1.164
0.005
1.533
0.007
1.776
0.004
Date: 7/16/18
Date:
% Error of
*
Full Span
0.25
0.15
0.25
0.35
0.20
7/20/2018