Travis Industries Medium Flush Wood Hybrid Fyre Insert Manual page 185

Table of Contents

Advertisement

OMNI-Test Laboratories, Inc.
– Particulate emissions for test run, g/hr
PM
R
ASTM E2780 equation (6)
PM
= 60 (E
R
Where,
E
T
θ = Total length of full integrated test run, min
Sample Calculation:
E
(Dual train average) =
T
θ =
PM
= 60 x ( 7.96 / 550 )
R
PM
R
Control No. P-SSAR-0003
/θ)
T
= Total particulate emissions, grams
7.96 g
550 min
= 0.87
g/hr
185 of 236
Run 2-Low_10-min

Advertisement

Table of Contents