OMNI-Test Laboratories, Inc.
– Particulate emission factor for test run, g/dry kg of fuel burned
PM
F
ASTM E2780 equation (7)
PM
Sample Calculation:
E
(Dual train average) =
T
Control No. P-SSAR-0003
= E
/M
F
T
FTAdb
7.96 g
M
=
8.60 kg
Bdb
PM
=
7.96 / 8.60
F
PM
=
0.93
g/kg
F