APRILIA RSV4 RR 2017 Service Station Manual page 196

Table of Contents

Advertisement

Electrical system
Low power supply voltage
Error cause
The throttle valve power supply voltage is too low to correctly perform the self-learning test
(at each key ON). The instrument panel does not indicate the presence of this error even in
the ATT status
Troubleshooting
Remove the presence of errors that prevent throttle self-learning.
Rear throttle valve position error P0638
Misalignment between control and activation
Error cause
The throttle valve mechanical control could be damaged
Troubleshooting
Replace the throttle body
Front throttle valve Limp Home self-learning P1406
Test failed
Error cause
Position of the throttle valve, maintained by the springs, outside the specified range (at each
key ON). The instrument panel does not indicate the presence of this error even in the ATT
status
Troubleshooting
Check the cleanliness of the throttle body and the intake duct. If ok replace the throttle body
Front throttle valve mechanical (re-closing) springs self-learning P1411
Test failed
Error cause
Throttle valve return time, in the position maintained by the springs, outside of the specified
limits: the causes can be a deterioration of spring performance or excessive throttle valve
friction (at each key ON)
Troubleshooting
Check the cleanliness of the throttle body and the intake duct. If ok replace the throttle body
Front throttle valve minimum mechanical position self-learning P1408
Test failed
Error cause
Position of the throttle valve stopper outside of the specified range (at each key ON)
Troubleshooting
ELE SYS - 196
RSV4 RR-RF

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rsv4 rf 2017

Table of Contents