Electrical system
TABLE C1 - PROCEDURE FOR CORRECT ABS
CONTROL UNIT CONNECTOR INSERTION
Place the connector on the opposite side of the
control unit and lower the driving lever until the
"click" that signals the end of the stroke is heard
TABLE C2 - PROCEDURE FOR CORRECT ABS
CONTROL UNIT CONNECTOR INSERTION
When the connector is fully inserted, the measured
distance between the connector and the ABS con-
trol unit must be 7.5 mm
TABLE C3 - PROCEDURE FOR CORRECT ABS
CONTROL UNIT CONNECTOR INSERTION
If the initial position of the connector and the pull-
ing level is not as the one shown in "TABLE C", the
connector will not hook correctly and the meas-
ured distance will be higher (around 12 mm).
In this case repeat the operation as described in
"TABLE C1/C2"
It is advisable to create a jig in order to check the
correct connector insertion.
WIRING TABLE D - ABS ON SADDLE MOUNT-
ING
Check that the connector has been inserted cor-
rectly, as described in the preceding TABLES
ELE SYS - 118
RSV4 RR-RF