RSV4 RR-RF
•
Circuit not functioning
Error cause:
•
Replace the injection control unit.
The instrument panel indicates this error by lighting up in a fixed manner the MI warning light.
NOTE
THIS ERROR GENERATES THE RECOVERY STATUS AND ENGINE SHUT-DOWN.
P0605 ROM Error
Electrical diagnosis:
•
Circuit not functioning
Error cause:
•
Replace the injection control unit.
The instrument panel indicates this error by lighting up in a fixed manner the MI warning light.
NOTE
THIS ERROR GENERATES THE RECOVERY STATUS AND ENGINE SHUT-DOWN.
P060B A/D converter
Electrical diagnosis:
•
Circuit not functioning
Error cause:
•
Replace the injection control unit.
The instrument panel indicates this error by lighting up in a fixed manner the MI warning light and by
flashing the general warning light.
NOTE
THIS ERROR GENERATES THE RECOVERY STATUS AND ENGINE SHUT-DOWN.
P1301 top lights relay error
Electrical diagnosis:
•
short circuit to positive / short circuit to negative / open circuit
Error cause:
•
Short-circuit to positive: excessive voltage has been detected on PIN 31.
•
If short circuit to negative: no voltage has been detected.
•
If open circuit: an interruption has been detected.
The instrument panel indicates this error by lighting up in a fixed manner the general warning light.
Troubleshooting
•
Short-circuit to positive: check the correct electrical characteristics of the relay by discon-
necting it from the wiring harness, if not ok replace the relay, if ok restore the wiring harness
(blue/pink cable)
Electrical system
ELE SYS - 143