Malfunction
No connection
established, no
image transmission.
The unit does not
report an alarm.
Control of cameras
or other devices is
not possible.
The unit is not
operational after
firmware upload.
Appendix
Possible causes
The unit's configuration.
Faulty installation.
Wrong IP address.
Faulty data transmission
within the LAN.
The maximum number of
connections has been
reached.
Alarm source is not selected. Select possible alarm sources on
No alarm response
specified.
The cable connection
between the serial interface
and the connected device is
incorrect.
The interface parameters
conflict with those of the
other device connected.
Power failure during
programming by the update
file.
Incorrect update file.
Installation and Operating Manual | VideoJet 8008
Solution
Check all configuration
parameters.
Check all cables, plugs, contacts
and connections.
Check the IP addresses (terminal
program).
Check the data transmission with
ping
.
Wait until there is a free connection
and call the transmitter again.
the Alarm sources configuration
page.
Specify the desired alarm response
on the Alarm connections
configuration page, if necessary
change the IP address.
Check all cable connections and
ensure all plugs are properly
plugged in.
Make sure the settings of all
devices involved are compatible.
Have the unit checked by
Customer Service and replace if
necessary.
Enter unit IP address followed by
/main.htm in the web browser
and repeat the upload.
Bosch Security Systems | 2005-06 | V2.0