Reflective Sensor Heads: FUN M ode Functions
l Default Settings
The settings are initialized to the default setting made at the factory. The
default settings are listed in the following table.
Mode
FUN
Scaling values
Number of samples to
average
Hysteresis
Hold Mode
Timer
Two-sensor operation
(when two Amplifier
Units are connected)
Special selection
Monitor focus function
Intensity Mode
Differentiation function
Display reverse function OFF (disabled)
ECO display function
Limited number of dis-
play digits
Settings for non-mea-
surement
Zero reset memory
function
Gain switch
T
HIGH threshold
LOW threshold
RUN
Sub-display function
Zero reset function
Function
Refer to 4-5-8 Initializing Settings.
Initial value
Maximum display value: Maximum
sensing distance
Minimum display value: Minimum
sensing distance
256 samples
1% of total sensing distance range
OFF (disabled)
OFF (disabled)
OFF (disabled)
CLOSE
4 V (20 mA): Maximum sensing dis-
tance
−4 V (4 mA): Minimum sensing dis-
tance
OFF (disabled)
OFF (disabled)
OFF (disabled)
All digits displayed
KEEP
ON
AUTO
Maximum sensing distance
Minimum sensing distance
Threshold values
OFF (disabled)
Section 3-5
65