3-8-10 Differentiation Function

The differentiation function is used to convert variations in measured val-
ues into output values. Use it for measurements that monitor changes in
measured values, such as counting the number of sheets.
When the Differentiation Mode is enabled, the number of cycles (measure-
ment period) to be compared can be set. (1 cycle: 150 μs)
Measured value
Example:
Number of samples
to average = 1
For 10 cycles
(Note: Default
setting =
5,000 cycles)
y
Differentiation value
Differentiation value changes
because of the difference
in the measured values.
Example: Measured Values and Differentiation Values
The variation in the measured values indicates the difference
between the previous and current measured values. This value will
decrease when the number of samples to average is increased.
POINT

3-8-11 Display Reverse Function

The display direction of the digital displays can be selected. Select either
forward or backward according to the mounting direction of the Amplifier
Unit.

3-8-12 ECO Display Function

The ECO display function can be enabled or disabled. When the ECO dis-
play function is enabled, the digital display will not light.
104
Only the measured values for "
10 cycles
Differentiation value is zero
because there is no difference
Refer to 4-5-11 Special FUN Mode Settings Related to Dis-
plays.
" are compared.
in the measured values.
Section 3-8
Time
Differentiation value changes
because of the difference
in the measured values.
Time