T (Threshold) Mode

4-4

T (Threshold) Mode

4-4-1

Teaching Procedures

n Position Teaching
With position teaching, the threshold values are set based on the values
for a workpiece. This teaching method ensures that the measured value
will be the ON threshold value after teaching.
Press the ENT Key.
The sub-display will light con-
tinuous after flashing twice.
118
Set the mode switch to T.
RUN
T
Select the threshold value that is to be
taught using the threshold switch.
H
Set the workpiece and press the ENT
Key for about 1 second while the sub-
display is lit.
The measured value of workpiece will
be displayed on the sub-display and it
will flash twice (all digits will flash
together).
The threshold value will be set after the
display flashes twice and then lights
continuously.
The threshold value will
not be modified if a
teaching error occurs.
POINT
Section 4-4
FUN
L