Electrical connection
Operating Instructions 52Xi, 52Xi-75 - 00.0 - 10/2021
7.2
Lighting transformer connection
to network voltage
DENGER
Risk of electric injury!
The lighting transformer is not switched-off by the
main switch (EN 60 204-31)! At the lighting
installation and repair works in the transformer
box, e.g. a fuse replacement, the network plug
must be disconnected from the network
unconditionally.
The machine is equipped with Efka DC1550/DA321G
Pic. 38: Efka control
① ② ③
(1) - Rubber bushing
(2) - Upper terminal
(3) - Lower terminal
1.
Pull the network plug form the socket.
2.
Screw out 4 screws on the front plate of the control box.
3.
Remove the front plate.
4.
Pull the cable of the lighting transformer through the canal (4)
in the control box.
5.
Take out the black rubber bushing (1).
6.
Pierce the bushing with a screwdriver.
7.
Pull the lighting transformer cable through the arisen hole.
8.
Put the rubber bushing back again.
(4) - Cable canal
(5) - Terminal openers