Axis [Group]
Synchronous group
Synchronous mode
Synchronous
condition
Current value
Unit
Deviation (Pulse)
Active table number
Starting table number
Operate/Stop
State of axis
Error code
Error clear
Warning code
Warning clear
Speed rate
Note:
If a recoverable error occurred in the positioning unit, click [Error Clear] to clear the error.
If a warning occurred in the positioning unit, click [Warning Clear] to clear the warning.
2. Click [Change] in the starting table number field to specify the starting table number.
Specify the starting table number and click [Operate] to start the positioning opration.
Note:
 In the positioning unit, the positioning operation for the interpolation group is performed to request the
start and stop for the smallest number of axes in the group.
 In the tool operation, the positioning operation for the interpolation group is performed by clicking
[Operate] for any axes. However, due to the above specifications, a warning message is shown when
any [Operate] button other than the one for the smallest axis number is clicked.
3. Click [Close] to close the dialog.
Note:
This dialog cannot be closed during the positioning operation.
The axis numbers and group names to be monitored.
The group name and the master/slave axis type fot the synchronous
operation.
The operation mode for the synchronous operation.
Monitor the synchronous/asynchronous condition in the synchronous
operation.
For the synchronous operation in the operation mode A, clicking
[Synchronous change] changes the condition.
Monitor the feedback value for every axis after unit conversion.
Clicking [Current value update] displays the dialog for inputting the value,
and it enables to change the current value.
Indicate the unit of positions for the axes specified in the parameter settings
each from the positioning unit.
Indicate the deviation when activating the moving amount automatic check
function.
Indicate the table number during the operation or when it completes.
The starting table number for the positioning control.
Click [Change] to change the starting table number.
Execute the operation to start/stop the home return.
・Click [Operate] to execute the positioning operation. The button name
changes to [Stop].
・Click [Stop] to execute the deceleration stop operation. The button name
changes to [Operate].
The operating states of axes or error and warning occurrences.
The latest error code when an error occurred.
Clear the error by clicking this button, when an error occurred.
Indicate the latest warning code when a warning occurs.
Clear the warning by clicking this button, when a warning occurred.
The target speed of the home return specified in the parameter settings for
each axis is regarded as 100%, and the operation is executed in the
specified speed rate.
Clicking [Speed rate] shows the dialog for inputting the value.
7-35