Removing Scratches From Bumper - Hussmann micro SC ARCH Series Installation & Operation Manual

Self-contained cold-wall bunker with lids
Table of Contents

Advertisement

M
4-2
aIntEnancE
Do Use:
•Remove the product and all loose debris to
avoid clogging the waste outlet .
•Store product in a refrigerated area such as a
cooler . Remove only as much product as can
be taken to the cooler in a timely manner .
•Thoroughly clean all surfaces with soap and
hot water . d
o not use steAm or high wAter
pressure hoses to wAsh the interior
t
hese will destroy the merchandisers
sealing causing leaks and poor performance
•Do NOT flood merchandiser with water .
n
ever introduce wAter fAster thAn the
wAste outlet cAn remove it
•Clean and dry equipment with a soft cloth .
Allow merchandisers to dry before resuming
operation .
•After cleaning is completed, turn on power
to the merchandiser . Allow case to reach
operational temperature before stocking with
product .

REMOVING SCRATCHES FROM BUMPER

Most scratches and dings can be removed
using the following procedure .
1 . Use steel wool to smooth out the surface
area of the bumper .
2 . Clean area .
3 . Apply vinyl or car wax and polish surface
for a smooth glossy finish .
P/N 3116321_A
.
'
.
.
U.S. & Canada 1-800-922-1919 • Mexico 1-800-890-2900 • www.hussmann.com
SHUT FANS OFF DURING
CLEANING PROCESS.
CLEANING CONDENSER
The condensing unit area may be cleaned
with a vacuum using a wand attachment to
suck up dirt and debris . It should be cleaned
at minimum of twice a year . While cleaning,
be careful not to bend any tube or disconnect
electrical wires . A dirty condenser blocks
normal airflow through the coils, which
increases energy consumption and reduces
performance .
NEVER USE SHARP OBJECTS AROUND
COILS. Do not puncture coils! Do not bend
fins . Contact an authorized service technician
if a coil is punctured, cracked, or otherwise
damaged . ICE in or on the coil indicates the
refrigeration and defrost cycle is not operating
properly . Contact an authorized service
technician to determine the cause of icing, and
to make adjustments as necessary . To maintain
product integrity, move all product to a cooler
until the unit has returned to normal operating
temperatures .
Wear Safety Glasses and Gloves
to perform this maintenance.