Refrigeration Sequence Of Operation; Defrost Gas Sequence Of Operation - Hussmann micro SC ARCH Series Installation & Operation Manual

Self-contained cold-wall bunker with lids
Table of Contents

Advertisement

P/N 3116321_A
REFRIGERATION SEQUENCE OF
OPERATION
Compressor
Evaporator
Filter Strainer
DEFROST GAS SEQUENCE OF
OPERATION
Compressor
Evaporator
Filter Strainer
During defrost, the defrost solenoid valve is energized and held open allowing the gas to be redirected
through the evaporator. Also the defrost condensate shown in the picture is energized. Defrost is temperture
terminated with a failsafe that is 45 minutes. Normally only 1 defrost per day is required.
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.
Skin Condenser
Capillary
Defrost Valve
Skin Condenser
Capillary
Defrost Valve
WOT Condenser
Filter Dryer
Defrost Line
WOT Condenser
Filter Dryer
Defrost Line
Island Self Contained R-290
2-7