Internal Commands Upon Error Generation

Meanings of "x" in error codes 1x10 to 1xYY
Code Command
Function
(Hex)
1
Continuous READ To continuously read necessary
data without stopping the tape
2
Continuous WRITE To continuously write necessary
data without stopping the tape
5
PREROLL
To transport the tape to a
position before the specified ID
6
New TAPE
To check for data on the loaded
tape
7
REWIND
To rewind the tape
8
EJECT
To eject the cassette from this
unit
E
FAST FWD
To fast-forward the tape
F
STOP
To set the tape to STANDBY
ON or OFF mode
D
Other commands
Meanings of "x" in error codes 2x01 to 2xYY
and 3x01 to 3xYY
Code
Command
(Hex)
0
Unspecified
It must be one of the following
functions, but cannot be
specified.
1
EJECT
To eject the cassette
2
UNTHREAD
To thread the tape into the
cassette
3
STOP
To stop tape transport
4
STANDBY-ON
To rotate the drum in tape stop
status
5
PLAY
To play the tape
6
CLEANING
To run the cleaning cassette for
the specified time
7
STANDBY-OFF
To stop the drum rotation in tape
stop status
8
REC
To record on the tape
9
FF
To forward the tape at the
highest speed.
A
REWIND
To rewind the tape at the
highest speed
B
PREROLL
To locate the specified point
according to the ID on the tape
C
IDC SEARCH
To locate the specified point
according to the internal
counter.
D
DIAG
Diagnosis in progress
F
Others
Functions that are not classified
in any of the above functions
Function