2. Refer to
Figure 3-19
GPIM-01, GPIM-08, or GPIM-09
application of the GBIC. Refer to
be used in the installation.
Figure 3-19 Fiber-optic GBIC Connections
➀
SC cable connector
➁
Latch keys (bottom of SC connector)
➂
GPIM-01, GPIM-08, or GPIM-09
3. At the other end of the fiber-optic cable, attach the SC connector to the other device. Verify that
a link exists by checking that the Link LED
on the LEDs. If the Link LED is OFF and the RX/TX LED ➄ is not blinking amber, perform
the following steps until it is ON:
a. Check that the device at the other end of the link has power turned on and is Gigabit Ethernet
compatible.
b. Verify proper crossover of fiber strands between the port on the device and the fiber-optic
device at the other end of the fiber-optic link segment.
c. Verify that the fiber-optic cable meets the specifications outlined in
installed GBIC.
To remove the SC connector from the GBIC, carefully pull the connector out of the port. It may need
to be moved gently from side to side to release the latching keys.
and insert one end of the SC cable connector
➂
. Ensure that the appropriate cable is used for the
Appendix A
Á
for the appropriate GBIC and fiber-optic cable to
Â
à Ä
À
➃
Link LED
➄
Receive/Transmit (RX/TX) LED
➃
is ON (solid green). Refer to
Connecting to the Network
➀
➁
, key side down
Chapter 4
for details
Appendix A
for the
Hardware Installation
, into the
3-27